Abstract
Objective. To determine the outcomes of and satisfaction with the multi-component inflatable penile prosthesis (IPP) in the elderly male (age >71). Methods. Using a chart review and telephone survey, we retrospectively assessed patients who underwent IPP or combined IPP/artificial urinary sphincter (AUS) from 2004-2006. Results. We identified 56 patients that underwent IPP (48) or IPP/AUS (8). The age range was 71-86 (mean 74.3) at the time of surgery, with a follow-up range of 0.5-2.4 years (mean 1.5). The overall complication rate was 3.8% (2 of 56) with one device removed for infection and a second patient requiring exploration for a postoperative hematoma. The telephone interview was conducted with 35 of 56 patients. Patients rated ease of use (a scale from 1-5, 5 meaning very easy) and overall satisfaction (a scale of 1-5, 5 meaning very satisfied) at an average of 4.1 and 4.3, respectively. IPP usage varied from 0-7 times per month (mean 3.3). 32 of 35 patients (91%) said they would undergo the procedure again. Conclusion. Our review demonstrates that the IPP is well tolerated in the elderly male population, who report a high degree of satisfaction and ease of use with this device.
References
-
- Arias E, Curtin LR, Wei R, Anderson RN. National Vital Statistics Reports. 1. Hyattsville, Md, USA: NCHS; 2008. U.S. Decennial life tables for 1999–2001, United States life tables. - PubMed
-
- Darouiche RO, Wall MJ, Jr., Itani KMF, et al. Chlorhexidine-alcohol versus povidone-iodine for surgical-site antisepsis. The New England Journal of Medicine. 2010;362(1):18–26. - PubMed
-
- Deveci S, Martin D, Parker M, Mulhall JP. Penile length alterations following penile prosthesis surgery. European Urology. 2007;51(4):1128–1131. - PubMed
-
- Carson CC, Mulcahy JJ, Govier FE. Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: results of a long-term multicenter study. Journal of Urology. 2000;164(2):376–380. - PubMed
-
- Levine LA, Estrada CR, Morgentaler A. Mechanical reliability and safety of, and patient satisfaction with the ambicor inflatable penile prosthesis: results of a 2 center study. Journal of Urology. 2001;166(3):932–937. - PubMed
LinkOut - more resources
Full Text Sources