A whole body transportable indirect calorimeter for human use in the tropics
Abstract
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Similar articles
-
Classical experiments in whole-body metabolism: open-circuit respirometry-diluted flow chamber, hood, or facemask systems.Eur J Appl Physiol. 2018 Jan;118(1):33-49. doi: 10.1007/s00421-017-3735-5. Epub 2017 Oct 27. Eur J Appl Physiol. 2018. PMID: 29080000 Free PMC article. Review.
-
Validity and reliability of a new portable telemetric calorimeter designed to measure oxygen consumption and carbon dioxide production.Diabetes Nutr Metab. 2001 Oct;14(5):268-76. Diabetes Nutr Metab. 2001. PMID: 11806467
-
A computer-controlled indirect calorimeter for the measurement of energy expenditure in one or two subjects simultaneously.Hum Nutr Clin Nutr. 1986 Jul;40(4):315-21. Hum Nutr Clin Nutr. 1986. PMID: 3744892
-
Measuring energy expenditure in community-dwelling older adults: are portable methods valid and acceptable?J Am Diet Assoc. 2008 Mar;108(3):544-8. doi: 10.1016/j.jada.2007.12.012. J Am Diet Assoc. 2008. PMID: 18313438
-
Some mathematical and technical issues in the measurement and interpretation of open-circuit indirect calorimetry in small animals.Int J Obes (Lond). 2006 Sep;30(9):1322-31. doi: 10.1038/sj.ijo.0803280. Epub 2006 Jun 27. Int J Obes (Lond). 2006. PMID: 16801931 Review.
Cited by
-
The contribution of Swiss scientists to the assessment of energy metabolism.Eur J Clin Nutr. 2018 May;72(5):665-679. doi: 10.1038/s41430-018-0139-5. Epub 2018 May 10. Eur J Clin Nutr. 2018. PMID: 29748652 Free PMC article. Review.
-
Validation of whole room indirect calorimeters: refinement of current methodologies.Physiol Rep. 2017 Nov;5(22):e13521. doi: 10.14814/phy2.13521. Physiol Rep. 2017. PMID: 29180485 Free PMC article.
-
Classical experiments in whole-body metabolism: open-circuit respirometry-diluted flow chamber, hood, or facemask systems.Eur J Appl Physiol. 2018 Jan;118(1):33-49. doi: 10.1007/s00421-017-3735-5. Epub 2017 Oct 27. Eur J Appl Physiol. 2018. PMID: 29080000 Free PMC article. Review.