Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2012 Oct;14(10):1490-7.
doi: 10.1093/europace/eus193. Epub 2012 Jun 13.

Cardiac resynchronization therapy after atrioventricular junction ablation for symptomatic atrial fibrillation: a meta-analysis

Affiliations
Meta-Analysis

Cardiac resynchronization therapy after atrioventricular junction ablation for symptomatic atrial fibrillation: a meta-analysis

Stavros Stavrakis et al. Europace. 2012 Oct.

Abstract

Aims: Atrioventricular junction (AVJ) ablation with permanent pacing improves symptoms in selected patients with atrial fibrillation (AF). The optimal pacing modality after AVJ ablation remains unclear. We performed a meta-analysis of randomized controlled trials to examine whether cardiac resynchronization therapy (CRT) is superior to right ventricular (RV) pacing in this patient population.

Methods and results: We searched the MEDLINE and EMBASE databases for studies evaluating the effect of CRT vs. RV pacing after AVJ ablation for AF. Pooled risk ratios (RRs) and mean differences with 95% confidence intervals (CIs) were calculated for categorical and continuous outcomes, respectively, using a random effects model. Five trials involving 686 patients (413 in CRT and 273 in RV pacing group) were included in the analysis. On the basis of the pooled estimate across the studies, CRT resulted in a non-significant reduction in mortality (RR = 0.75, 95% CI 0.43-1.30; P= 0.30) and a significant reduction in hospitalizations for heart failure (RR = 0.38, 95% CI = 0.17-0.85; P= 0.02) compared with RV pacing. Cardiac resynchronization therapy did not improve 6 min walk distance (mean difference 15.7, 95% CI -7.2 to 38.5 m; P= 0.18) and Minnesota Living with Heart Failure quality-of-life score (mean difference -3.0, 95% CI -8.6 to 2.6; P= 0.30) compared with RV pacing. The change in left ventricular ejection fraction between baseline and 6 months favoured CRT (mean change 2.0%, 95% CI 1.5-2.4%; P< 0.001).

Conclusion: Cardiac resynchronization therapy may be superior to RV pacing in patients undergoing AVJ ablation for AF. Further studies, adequately powered to detect clinical outcomes, are required.

PubMed Disclaimer

Comment in

Publication types

MeSH terms