Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Oct;27(8):771-6.
doi: 10.1016/j.clinbiomech.2012.05.008. Epub 2012 Jun 16.

Comparison of four reconstruction methods after total sacrectomy: a finite element study

Affiliations
Comparative Study

Comparison of four reconstruction methods after total sacrectomy: a finite element study

Rui Zhu et al. Clin Biomech (Bristol). 2012 Oct.

Abstract

Background: After total sacrectomy, it is mandatory to reconstruct the continuity between the lumbar spine and the pelvis. Only few biomechanical analyses exist which compare different reconstructions. Therefore, the aim of this study was to compare the lumbo-pelvic motion and the relative risk of implant breakage for four different reconstructions after total sacrectomy.

Method: Finite element analyses were performed for four general different reconstructions after total sacrectomy: sacral-rod reconstruction, four-rod reconstruction, bilateral fibular flaps reconstruction, and improved compound reconstruction. The rotations between L5 vertebra and ilium, the L5 shift-down displacement, and the maximum von Mises stress in the implants were calculated and evaluated for flexion, extension, lateral bending and axial rotation.

Findings: The decreasing order of the rotations between L5 vertebra and ilium as well as of the L5 shift-down displacement for the studied reconstruction methods was four-rod reconstruction>sacral-rod reconstruction>bilateral fibular flaps reconstruction>improved compound reconstruction. The decreasing order of the maximum von Mises stress in the implants was sacral-rod reconstruction>four-rod reconstruction>bilateral fibular flaps reconstruction>improved compound reconstruction.

Interpretation: From the mechanical point of view, improved compound reconstruction is superior to the other methods studied here as it shows the highest stability and the lowest maximum von Mises stress. However, clinical aspects must also be regarded when choosing a reconstruction method for a specific patient.