AAA with a challenging neck: early outcomes using the Endurant stent-graft system
- PMID: 22705160
- DOI: 10.1016/j.ejvs.2012.04.031
AAA with a challenging neck: early outcomes using the Endurant stent-graft system
Abstract
Objectives: The efficacy and safety of endovascular aneurysm repair is disputable in aneurysms with a short, angulated, wide, conical, or thrombus-lined neck making a reliable seal difficult to achieve. The influence of a challenging neck on early results using the Endurant stent-graft system in high risk patients was investigated.
Materials and methods: A retrospective study conducted on a prospectively compiled database of 72 elective patients with challenging neck treated with the Endurant system (Endurant Stent Graft, Medtronic AVE, Santa Rosa, CA, USA). These patients were compared to a control group (n = 65) without significant neck problems. Endpoints were early technical and clinical success, deployment accuracy and differences in operative details at one month follow-up. Data are reported as mean and standard deviation or as absolute frequency and percentage (%). Normality distribution and homogeneity of variances were tested by Shapiro-Wilks and Levene tests, respectively. Inter-group comparisons for each variable were made by t-test or χ2-test or Fisher exact test. A p < 0.05 was considered statistically significant.
Results: Mean age was 76.12 years; 76.6% were males. Risk factors and pre-operative variables did not differ significantly between the two groups. Mean neck length was 10.56 mm in patients with challenging anatomies and 22.85 mm in controls. Patients with a challenging neck differed significantly (p < 0.001) from controls in terms of mean infrarenal (37.67° vs. 20.12°) and suprarenal angle (19.63° vs. 15.57°); 82% of patients with a challenging neck were ASA III/IV (vs. 86%). Technical success was 100%, with four unplanned proximal extension in challenging group. No type I endoleaks or aneurysm-related deaths occurred in either group; major complications were 1.54% vs. 1.39% (p = 0.942). Operative details were similar in both groups.
Conclusion: Treatment with the Endurant stent-graft is technically feasible and safe, yielding satisfactory results even in challenging anatomies. Medium- and long-term data are needed to verify durability, but early results are promising.
Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Comment in
-
Commentary on 'AAA with a challenging neck: early outcomes using the Endurant stent-graft system'.Eur J Vasc Endovasc Surg. 2012 Sep;44(3):280. doi: 10.1016/j.ejvs.2012.05.021. Epub 2012 Jul 12. Eur J Vasc Endovasc Surg. 2012. PMID: 22795535 No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources