Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles
- PMID: 22712910
- DOI: 10.1121/1.4707512
Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles
Abstract
Sub-harmonic response from ultrasound contrast agent microbubbles has been demonstrated to be an effective modality for noninvasive pressure measurement. In the present study, the dependence of ultra-harmonic response on the ambient overpressure was investigated by both experimental measurements and simulations. In the measurements, the microbubbles were exposed to Gaussian pulses with varied driving frequencies and pulse lengths, at an acoustic pressure of 0.3 MPa. The amplitudes of sub- and ultra-harmonic components were measured when the ambient overpressures varied from 0-25 kPa. At the driving frequency of 1.33 MHz, the ultra-harmonic energy decreased but the sub-harmonic energy increased with the increasing overpressure; while at the driving frequency of 4 MHz, both the sub- and ultra-harmonic components showed the same tendency that the corresponding energy decreased as the overpressure was increased. A 4-MHz Gaussian pulse with 64 cycles could provide an ultra-harmonic response with both good ambient pressure sensitivity and high linearity. Furthermore, the effects of shell parameters of a microbubble on the generation of ultra- and sub-harmonic responses were discussed based on simulations using Marmottant's model. This study suggests that the ultra-harmonic response from contrast microbubbles might be applicable for noninvasive pressure measurement.
Similar articles
-
Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubbles.Phys Med Biol. 2011 Oct 7;56(19):6459-73. doi: 10.1088/0031-9155/56/19/018. Epub 2011 Sep 20. Phys Med Biol. 2011. PMID: 21934190
-
Ambient pressure sensitivity of microbubbles investigated through a parameter study.J Acoust Soc Am. 2009 Dec;126(6):3350-8. doi: 10.1121/1.3242359. J Acoust Soc Am. 2009. PMID: 20000949
-
Simulation of noninvasive blood pressure estimation using ultrasound contrast agent microbubbles.IEEE Trans Ultrason Ferroelectr Freq Control. 2012 Apr;59(4):715-26. doi: 10.1109/TUFFC.2012.2249. IEEE Trans Ultrason Ferroelectr Freq Control. 2012. PMID: 22547282
-
Subharmonic behavior of phospholipid-coated ultrasound contrast agent microbubbles.J Acoust Soc Am. 2010 Nov;128(5):3239-52. doi: 10.1121/1.3493443. J Acoust Soc Am. 2010. PMID: 21110619
-
Nonlinear shell behavior of phospholipid-coated microbubbles.Ultrasound Med Biol. 2010 Dec;36(12):2080-92. doi: 10.1016/j.ultrasmedbio.2010.08.015. Epub 2010 Oct 28. Ultrasound Med Biol. 2010. PMID: 21030140
Cited by
-
The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent.Ultrasound Med Biol. 2014 Apr;40(4):727-38. doi: 10.1016/j.ultrasmedbio.2014.01.002. Ultrasound Med Biol. 2014. PMID: 24582298 Free PMC article.
-
Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound.J Acoust Soc Am. 2014 Feb;135(2):646-53. doi: 10.1121/1.4843175. J Acoust Soc Am. 2014. PMID: 25234874 Free PMC article.
-
Acoustic response and ambient pressure sensitivity characterization of SonoVue for noninvasive pressure estimation.J Acoust Soc Am. 2024 Apr 1;155(4):2636-2645. doi: 10.1121/10.0025690. J Acoust Soc Am. 2024. PMID: 38629883 Free PMC article.
-
Focused Ultrasound for Noninvasive, Focal Pharmacologic Neurointervention.Front Neurosci. 2020 Jul 14;14:675. doi: 10.3389/fnins.2020.00675. eCollection 2020. Front Neurosci. 2020. PMID: 32760238 Free PMC article. Review.
-
Transcranial cavitation detection in primates during blood-brain barrier opening--a performance assessment study.IEEE Trans Ultrason Ferroelectr Freq Control. 2014 Jun;61(6):966-78. doi: 10.1109/TUFFC.2014.2992. IEEE Trans Ultrason Ferroelectr Freq Control. 2014. PMID: 24859660 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources