Eight-parameter PC-AT based flow cytometric data system
- PMID: 2272245
- DOI: 10.1002/cyto.990110706
Eight-parameter PC-AT based flow cytometric data system
Abstract
An 8-parameter flow cytometric data system is described using an IBM-AT compatible personal computer (PC) and a commercial analog to digital conversion (ADC) board. A dedicated pulse processing interface adapts the flow cytometric pulses to the ADC board and controls the number of parameters to be taken up and the trigger conditions. The trigger thresholds are automatically held at a level immediately above the noise level. For the timing of kinetic measurements a linear voltage ramp of adjustable rise time is available. A built-in precision voltage source can be used for an overall calibration. The data system is operated by software written in assembly language. Data may be collected and processed in 1-8-parameter listmode or 1-3-parameter histogram mode. Functions are available for graphical color displays, numerical integration, multiparameter gating, and printing.
Similar articles
-
Application of the CYTOMIC 12 flow cytometric compact analyzer for automatic kinetic measurements.Cytometry. 1983 Jan;3(4):244-50. doi: 10.1002/cyto.990030403. Cytometry. 1983. PMID: 6822145
-
An innovation in flow cytometry data collection and analysis producing a correlated multiple sample analysis in a single file.Cytometry. 1991;12(1):82-90. doi: 10.1002/cyto.990120112. Cytometry. 1991. PMID: 1999125
-
Integration of a barcode reader with a commercial flow cytometer.Cytometry. 1992;13(2):193-7. doi: 10.1002/cyto.990130214. Cytometry. 1992. PMID: 1547668
-
Cluster analysis of flow cytometric list mode data on a personal computer.Cytometry. 1993;14(6):649-59. doi: 10.1002/cyto.990140609. Cytometry. 1993. PMID: 8404371
-
"Cytomic" data system modules--modern electronic devices for flow cytometric data handling and presentation.Cytometry. 1984 May;5(3):299-303. doi: 10.1002/cyto.990050313. Cytometry. 1984. PMID: 6734354
Cited by
-
Quantifying heterogeneity: flow cytometry of bacterial cultures.Antonie Van Leeuwenhoek. 1991 Oct-Nov;60(3-4):145-58. doi: 10.1007/BF00430362. Antonie Van Leeuwenhoek. 1991. PMID: 1725477 Review.
-
Flow cytometry and cell sorting of heterogeneous microbial populations: the importance of single-cell analyses.Microbiol Rev. 1996 Dec;60(4):641-96. doi: 10.1128/mr.60.4.641-696.1996. Microbiol Rev. 1996. PMID: 8987359 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources