Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system
- PMID: 22722898
- DOI: 10.1007/s11517-012-0932-6
Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system
Abstract
Non-invasive continuous glucose monitoring (NI-CGM) sensors are still at an early stage of development, but, in the near future, they could become particularly appealing in diabetes management. Solianis Monitoring AG (Zurich, Switzerland) has proposed an approach for NI-CGM based on a multi-sensor concept, embedding primarily dielectric spectroscopy and optical sensors. This concept requires a mathematical model able to estimate glucose levels from the 150 channels directly measured through the Multisensor. A static multivariate linear regression model (with order and parameters common to the entire population of subjects) was proposed for such a scope (Caduff et al., Biosens Bioelectron 26:3794-3800, 2011). The aim of this work is to evaluate the accuracy in the estimation of glucose levels and trends that the NI-CGM Multisensor platform can achieve by exploiting different techniques for model identification, namely, ordinary least squares, subset variable selection, partial least squares and least absolute shrinkage and selection operator (LASSO). Data collected in human beings monitored for a total of 45 study days were used for model identification and model test. Several metrics of standard use in the diabetes scientific community to measure point and clinical accuracy of glucose sensors were used to assess the models. Results indicate that the LASSO technique is superior to the others shrinking many channel weights to zero thus leading to smoother glucose profiles and resulting in a more robust model to possible artifacts in the Multisensor data. Although, as expected, the performance of the NI-CGM system with the LASSO model is not yet comparable with that of enzyme-based needle glucose sensors, glucose trends are satisfactorily estimated. Considering the non-invasive nature of the multi-sensor platform, this result can have an immediate impact in the current clinical practice, e.g., to integrate sparse self-monitoring of blood glucose data with an indication of the glucose trend to aid the diabetic patient in dealing with, or even preventing in the short time scale, the threats of critical events such as hypoglycaemia.
Similar articles
-
Non-invasive continuous glucose monitoring with multi-sensor systems: a Monte Carlo-based methodology for assessing calibration robustness.Sensors (Basel). 2013 Jun 3;13(6):7279-95. doi: 10.3390/s130607279. Sensors (Basel). 2013. PMID: 23736850 Free PMC article.
-
Assessment of linear regression techniques for modeling multisensor data for non-invasive continuous glucose monitoring.Annu Int Conf IEEE Eng Med Biol Soc. 2011;2011:2538-41. doi: 10.1109/IEMBS.2011.6090702. Annu Int Conf IEEE Eng Med Biol Soc. 2011. PMID: 22254858
-
A Personalized Week-to-Week Updating Algorithm to Improve Continuous Glucose Monitoring Performance.J Diabetes Sci Technol. 2017 Nov;11(6):1070-1079. doi: 10.1177/1932296817734367. Epub 2017 Oct 16. J Diabetes Sci Technol. 2017. PMID: 29032732 Free PMC article.
-
Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.Biosensors (Basel). 2018 Mar 13;8(1):24. doi: 10.3390/bios8010024. Biosensors (Basel). 2018. PMID: 29534053 Free PMC article. Review.
-
Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges.Sensors (Basel). 2016 Dec 9;16(12):2093. doi: 10.3390/s16122093. Sensors (Basel). 2016. PMID: 27941663 Free PMC article. Review.
Cited by
-
Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device.Sensors (Basel). 2019 Aug 24;19(17):3677. doi: 10.3390/s19173677. Sensors (Basel). 2019. PMID: 31450547 Free PMC article.
-
Non-invasive continuous glucose monitoring with multi-sensor systems: a Monte Carlo-based methodology for assessing calibration robustness.Sensors (Basel). 2013 Jun 3;13(6):7279-95. doi: 10.3390/s130607279. Sensors (Basel). 2013. PMID: 23736850 Free PMC article.
-
Future Perspectives in Glucose Monitoring Sensors.Eur Endocrinol. 2013 Mar;9(1):6-11. doi: 10.17925/EE.2013.09.01.21. Epub 2013 Mar 15. Eur Endocrinol. 2013. PMID: 30349603 Free PMC article. Review.
-
The Effect of a Global, Subject, and Device-Specific Model on a Noninvasive Glucose Monitoring Multisensor System.J Diabetes Sci Technol. 2015 Jul;9(4):865-72. doi: 10.1177/1932296815579459. Epub 2015 Apr 24. J Diabetes Sci Technol. 2015. PMID: 25910542 Free PMC article.
-
First Experiences With a Wearable Multisensor in an Outpatient Glucose Monitoring Study, Part I: The Users' View.J Diabetes Sci Technol. 2018 May;12(3):562-568. doi: 10.1177/1932296817750932. Epub 2018 Jan 14. J Diabetes Sci Technol. 2018. PMID: 29332423 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical