[Locking attachment plate - first experience]
- PMID: 22723072
- DOI: 10.1055/s-0031-1298530
[Locking attachment plate - first experience]
Abstract
Background: In this paper we present our first experience in the application of a new, fixed-angle plate fixation: the locking attachment plate (LAP, Synthes, Oberdorf, Switzerland). We examined whether the LAP is a useful addition to the existing technical palette for periprosthetic fractures. The LAP is used for periprosthetic fractures with stable prostheses or intramedullary implants. The plate can be installed, e.g., on a 4.5 mm locking compression plate (LCP). Locking screws or cortical screws can be placed through its 4 diagonal fixed-angle arms, bicortical around the prosthesis stem into the bone. The LAP is designed to prevent lateral screw pull-out, to stabilise the prosthesis stem and thus to allow early postoperative mobilisation of patients.
Patients and methods: We implanted the LAP by operative fracture-treatment in the ORIF technique in 17 patients with periprosthetic fractures of the femur, tibia and humerus. The follow-up was at least 13 months.
Results: There were two losses to follow-up: the patients died a few weeks postoperatively. There was a total of two of 17 cases with infection events (11.8 %). We could examine 15 patients for follow-up. Eleven of these 15 patients regained their original range of motion (ROM) and nine of 15 patients their pretraumatic mobility. In all cases with periprosthetic humeral fractures we detected muscular deficits. In five out of 15 cases (33.3 %) no radiological fracture healing could be observed. Nevertheless in 14 of 15 cases the implant was stable without signs of implant or prosthetic loosening. There was no case of material failure.
Conclusion: Periprosthetic fractures are an increasingly common complication in old, often multi-morbid patients. A contemporary therapeutic intervention and early postoperative mobilisation contribute substantially to the success of treatment. The first results in the use of the LAP as a new implant option for periprosthetic fractures of the femur, tibia and humerus are promising. Further studies are necessary to show whether our overall good results are reproducible in larger groups of patients and whether the LAP can be given a firm position in the technical repertoire for treatment of periprosthetic fractures.
Georg Thieme Verlag KG Stuttgart · New York.
Similar articles
-
[Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].Acta Chir Orthop Traumatol Cech. 2009 Dec;76(6):473-8. Acta Chir Orthop Traumatol Cech. 2009. PMID: 20067694 Czech.
-
Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients.Injury. 2007 Jun;38(6):725-33. doi: 10.1016/j.injury.2007.02.038. Epub 2007 May 2. Injury. 2007. PMID: 17477923
-
Minimally invasive periprosthetic plate osteosynthesis using the locking attachment plate.Oper Orthop Traumatol. 2013 Aug;25(4):398-408, 410. doi: 10.1007/s00064-011-0091-1. Oper Orthop Traumatol. 2013. PMID: 23801040 Clinical Trial.
-
[Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].Unfallchirurg. 2012 Nov;115(11):1009-21. doi: 10.1007/s00113-012-2317-6. Unfallchirurg. 2012. PMID: 23143032 Review. German.
-
Indications and limitations of locked plating.Injury. 2009 Jul;40(7):683-91. doi: 10.1016/j.injury.2009.01.003. Epub 2009 May 22. Injury. 2009. PMID: 19464682 Review.
Cited by
-
Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures.Geriatr Orthop Surg Rehabil. 2022 May 3;13:21514593221100417. doi: 10.1177/21514593221100417. eCollection 2022. Geriatr Orthop Surg Rehabil. 2022. PMID: 35529896 Free PMC article.
-
Does an additional attachment plate improve fixation in Vancouver type B1 and C periprosthetic femoral fractures? A retrospective comparative study.BMC Musculoskelet Disord. 2025 May 22;26(1):505. doi: 10.1186/s12891-025-08762-1. BMC Musculoskelet Disord. 2025. PMID: 40405191 Free PMC article.
-
LOQTEQ® VA Periprosthetic Plate-A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note.J Clin Med. 2022 Feb 23;11(5):1184. doi: 10.3390/jcm11051184. J Clin Med. 2022. PMID: 35268275 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials