Improving diffusion MRI using simultaneous multi-slice echo planar imaging
- PMID: 22732564
- PMCID: PMC3429710
- DOI: 10.1016/j.neuroimage.2012.06.033
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Abstract
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high g-factor penalties (i.e., lower SNR). The CAIPIRINHA technique was developed to reduce the g-factor in simultaneous multi-slice acquisitions by introducing inter-slice image shifts and thus increase the distance between aliased voxels. Because the CAIPIRINHA technique achieved this by controlling the phase of the RF excitations for each line of k-space, it is not directly applicable to single-shot EPI employed in conventional diffusion imaging. We adopt a recent gradient encoding method, which we termed "blipped-CAIPI", to create the image shifts needed to apply CAIPIRINHA to EPI. Here, we use pseudo-multiple replica SNR and bootstrapping metrics to assess the performance of the blipped-CAIPI method in 3× simultaneous multi-slice diffusion studies. Further, we introduce a novel image reconstruction method to reduce detrimental ghosting artifacts in these acquisitions. We show that data acquisition times for Q-ball and diffusion spectrum imaging (DSI) can be reduced 3-fold with a minor loss in SNR and with similar diffusion results compared to conventional acquisitions.
Copyright © 2012 Elsevier Inc. All rights reserved.
Figures









Similar articles
-
Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty.Magn Reson Med. 2012 May;67(5):1210-24. doi: 10.1002/mrm.23097. Epub 2011 Aug 19. Magn Reson Med. 2012. PMID: 21858868 Free PMC article.
-
Simultaneous multislice accelerated interleaved EPI DWI using generalized blipped-CAIPI acquisition and 3D K-space reconstruction.Magn Reson Med. 2017 Apr;77(4):1593-1605. doi: 10.1002/mrm.26249. Epub 2016 Apr 19. Magn Reson Med. 2017. PMID: 27090059
-
Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.Invest Radiol. 2015 Jul;50(7):456-63. doi: 10.1097/RLI.0000000000000151. Invest Radiol. 2015. PMID: 25811832
-
Rapid brain MRI acquisition techniques at ultra-high fields.NMR Biomed. 2016 Sep;29(9):1198-221. doi: 10.1002/nbm.3478. Epub 2016 Feb 2. NMR Biomed. 2016. PMID: 26835884 Free PMC article. Review.
-
Diffusion tensor imaging and beyond.Magn Reson Med. 2011 Jun;65(6):1532-56. doi: 10.1002/mrm.22924. Epub 2011 Apr 5. Magn Reson Med. 2011. PMID: 21469191 Free PMC article. Review. No abstract available.
Cited by
-
Fast dictionary-based reconstruction for diffusion spectrum imaging.IEEE Trans Med Imaging. 2013 Nov;32(11):2022-33. doi: 10.1109/TMI.2013.2271707. Epub 2013 Jul 4. IEEE Trans Med Imaging. 2013. PMID: 23846466 Free PMC article.
-
Optimization of simultaneous multislice EPI for concurrent functional perfusion and BOLD signal measurements at 7T.Magn Reson Med. 2017 Jul;78(1):121-129. doi: 10.1002/mrm.26351. Epub 2016 Jul 28. Magn Reson Med. 2017. PMID: 27465273 Free PMC article.
-
Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses.Magn Reson Med. 2013 May;69(5):1261-7. doi: 10.1002/mrm.24719. Epub 2013 Mar 6. Magn Reson Med. 2013. PMID: 23468087 Free PMC article.
-
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging.J Magn Reson. 2013 Apr;229:90-100. doi: 10.1016/j.jmr.2013.02.002. Epub 2013 Feb 13. J Magn Reson. 2013. PMID: 23473893 Free PMC article. Review.
-
Simultaneous multislice echo-planar diffusion-weighted imaging (DWI) in patients with focal liver lesions: a comparative study with conventional DWI.Quant Imaging Med Surg. 2024 Sep 1;14(9):6684-6697. doi: 10.21037/qims-24-341. Epub 2024 Aug 28. Quant Imaging Med Surg. 2024. PMID: 39281149 Free PMC article.
References
-
- Andersson JL, Skare S, Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage. 2003;20:870–888. - PubMed
-
- Basser PJ, Mattiello J, LeBihan D. Estimation of the effective self-diffusion tensor from the NMR spin echo. J. Magn. Reson. B. 1994;103:247–254. - PubMed
-
- Blaimer M, Breuer FA, Seiberlich N, Mueller MF, Heidemann RM, Jellus V, Wiggins G, Wald LL, Griswold MA, Jakob PM. Accelerated volumetric MRI with a SENSE/GRAPPA combination. J. Magn. Reson. Imaging. 2006;24:444–450. - PubMed
-
- Bodammer N, Kaufmann J, Kanowski M, Tempelmann C. Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Magn. Reson. Med. 2004;51:188–193. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical