Argon laser trabeculoplasty with standard and long duration
- PMID: 2275355
- DOI: 10.1111/j.1755-3768.1990.tb04791.x
Argon laser trabeculoplasty with standard and long duration
Abstract
A prospective study of 0.1 sec and 0.2 sec duration argon laser trabeculoplasty was undertaken in 33 patients with chronic simple glaucoma. Patients were randomly allocated to receive 0.1 sec trabeculoplasty to the eye and 0.2 sec trabeculoplasty to the other. No difference was found in the fall in intra-ocular pressure or in glaucoma control between the two durations over the six months of the study. However, 0.2 sec argon laser trabeculoplasty was reported to be more uncomfortable of 60% of patients.
Similar articles
-
Two-year follow-up of intra-ocular pressure control with long duration argon laser trabeculoplasty.Acta Ophthalmol (Copenh). 1993 Jun;71(3):327-31. doi: 10.1111/j.1755-3768.1993.tb07143.x. Acta Ophthalmol (Copenh). 1993. PMID: 8362631 Clinical Trial.
-
Standard and long duration repeat argon laser trabeculoplasty.Acta Ophthalmol (Copenh). 1990 Oct;68(5):575-8. doi: 10.1111/j.1755-3768.1990.tb04790.x. Acta Ophthalmol (Copenh). 1990. PMID: 2275354
-
Argon laser trabeculoplasty or trabeculectomy a prospective randomised block study.Trans Ophthalmol Soc U K (1962). 1985;104 ( Pt 1):55-61. Trans Ophthalmol Soc U K (1962). 1985. PMID: 3855337 Clinical Trial.
-
Mechanisms of action and efficacy of argon laser trabeculoplasty and selective laser trabeculoplasty.Curr Opin Ophthalmol. 2007 Mar;18(2):140-5. doi: 10.1097/ICU.0b013e328086aebf. Curr Opin Ophthalmol. 2007. PMID: 17301616 Review.
-
Argon laser trabeculoplasty: a review.J Am Optom Assoc. 1992 Apr;63(4):252-6. J Am Optom Assoc. 1992. PMID: 1587990 Review.
Cited by
-
Laser trabeculoplasty for open angle glaucoma.Cochrane Database Syst Rev. 2007 Oct 17;2007(4):CD003919. doi: 10.1002/14651858.CD003919.pub2. Cochrane Database Syst Rev. 2007. PMID: 17943806 Free PMC article.
-
Laser trabeculoplasty for open-angle glaucoma and ocular hypertension.Cochrane Database Syst Rev. 2022 Aug 9;8(8):CD003919. doi: 10.1002/14651858.CD003919.pub3. Cochrane Database Syst Rev. 2022. PMID: 35943114 Free PMC article.
-
Membrane formation in the chamber angle after failure of argon laser trabeculoplasty: analysis of risk factors.Br J Ophthalmol. 2000 Jan;84(1):48-53. doi: 10.1136/bjo.84.1.48. Br J Ophthalmol. 2000. PMID: 10611099 Free PMC article.