A new method for long-term lumbar pressure monitoring with a fiber optic catheter
- PMID: 2275425
- DOI: 10.1007/BF01669997
A new method for long-term lumbar pressure monitoring with a fiber optic catheter
Abstract
A new method for long-term monitoring of cerebrospinal fluid (CSF) pressure in the spinal canal using a catheter with a fiberoptic pressure monitor is described. This method has been used in the investigation of 16 patients with communicating hydrocephalus (CH). Duration of monitoring ranged from 2-48 hours without any complications. In 6 cases the recording was interrupted prematurely. Valuable data on the patterns of pressure variation could be attained and the occurrence of B-waves showed a good correlation with the clinical outcome of shunt operation. No sign of external or internal leakage of CSF was observed during the first 24 hours of monitoring. This technique could prove to be a less invasive method for evaluation of CSF-pressure in patients with CH or other diseases where CSF-pressure in the spinal canal can have some clinical significance.
Similar articles
-
CSF outflow resistance as predictor of shunt function. A long-term study.Acta Neurol Scand. 2004 Sep;110(3):154-60. doi: 10.1111/j.1600-0404.2004.00302.x. Acta Neurol Scand. 2004. PMID: 15285771 Clinical Trial.
-
Intraventricular or lumbar infusion test in adult communicating hydrocephalus? Practical consequences and clinical outcome of shunt operation.Acta Neurochir (Wien). 2005 Oct;147(10):1027-35; discussion 1035-6. doi: 10.1007/s00701-005-0589-0. Epub 2005 Aug 1. Acta Neurochir (Wien). 2005. PMID: 16044359
-
Lumbar cerebral spinal fluid drainage during long-term electrocorticographic monitoring with subdural strip electrodes: elimination of cerebral spinal fluid leak.Seizure. 1993 Jun;2(2):133-6. doi: 10.1016/s1059-1311(05)80117-7. Seizure. 1993. PMID: 8167964
-
The predictive value of cerebrospinal fluid dynamic tests in patients with th idiopathic adult hydrocephalus syndrome.Arch Neurol. 1995 Aug;52(8):783-9. doi: 10.1001/archneur.1995.00540320059013. Arch Neurol. 1995. PMID: 7639630 Review.
-
Intracranial pressure measurement/cranial vault mechanics: clinical and experimental observations.Curr Opin Neurol Neurosurg. 1992 Dec;5(6):818-25. Curr Opin Neurol Neurosurg. 1992. PMID: 1467573 Review.
Cited by
-
The fidelity and dynamic response of fluid-filled catheter systems for direct measurement of lumbar cerebrospinal fluid pressure.J Clin Monit. 1993 Nov;9(5):314-20. doi: 10.1007/BF01618670. J Clin Monit. 1993. PMID: 8106883
-
Testing of cerebrospinal compensatory reserve in shunted and non-shunted patients: a guide to interpretation based on an observational study.J Neurol Neurosurg Psychiatry. 1996 May;60(5):549-58. doi: 10.1136/jnnp.60.5.549. J Neurol Neurosurg Psychiatry. 1996. PMID: 8778261 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources