A multi-view time-domain non-contact diffuse optical tomography scanner with dual wavelength detection for intrinsic and fluorescence small animal imaging
- PMID: 22755630
- DOI: 10.1063/1.4726016
A multi-view time-domain non-contact diffuse optical tomography scanner with dual wavelength detection for intrinsic and fluorescence small animal imaging
Abstract
We present a non-contact diffuse optical tomography (DOT) scanner with multi-view detection (over 360°) for localizing fluorescent markers in scattering and absorbing media, in particular small animals. It relies on time-domain detection after short pulse laser excitation. Ultrafast time-correlated single photon counting and photomultiplier tubes are used for time-domain measurements. For light collection, seven free-space optics non-contact dual wavelength detection channels comprising 14 detectors overall are placed around the subject, allowing the measurement of time point-spread functions at both excitation and fluorescence wavelengths. The scanner is endowed with a stereo camera pair for measuring the outer shape of the subject in 3D. Surface and DOT measurements are acquired simultaneously with the same laser beam. The hardware and software architecture of the scanner are discussed. Phantoms are used to validate the instrument. Results on the localization of fluorescent point-like inclusions immersed in a scattering and absorbing object are presented. The localization algorithm relies on distance ranging based on the measurement of early photons arrival times at different positions around the subject. This requires exquisite timing accuracy from the scanner. Further exploiting this capability, we show results on the effect of a scattering hetereogenity on the arrival time of early photons. These results demonstrate that our scanner provides all that is necessary for reconstructing images of small animals using full tomographic reconstruction algorithms, which will be the next step. Through its free-space optics design and the short pulse laser used, our scanner shows unprecedented timing resolution compared to other multi-view time-domain scanners.
Similar articles
-
Transmission and fluorescence angular domain optical projection tomography of turbid media.Appl Opt. 2009 Nov 20;48(33):6448-57. doi: 10.1364/AO.48.006448. Appl Opt. 2009. PMID: 19935964
-
Time-domain geometrical localization of point-like fluorescence inclusions in turbid media with early photon arrival times.Appl Opt. 2013 Aug 20;52(24):5985-99. doi: 10.1364/AO.52.005985. Appl Opt. 2013. PMID: 24085003
-
Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging.Phys Med Biol. 2005 Dec 7;50(23):5421-41. doi: 10.1088/0031-9155/50/23/001. Epub 2005 Nov 8. Phys Med Biol. 2005. PMID: 16306643
-
Multiparametric Time-Correlated Single Photon Counting Luminescence Microscopy.Biochemistry (Mosc). 2019 Jan;84(Suppl 1):S51-S68. doi: 10.1134/S0006297919140049. Biochemistry (Mosc). 2019. PMID: 31213195 Review.
-
Imaging orbitals with attosecond and Ångström resolutions: toward attochemistry?Rep Prog Phys. 2012 Jun;75(6):062401. doi: 10.1088/0034-4885/75/6/062401. Epub 2012 May 17. Rep Prog Phys. 2012. PMID: 22790647 Review.
Cited by
-
Alignment of sources and detectors on breast surface for noncontact diffuse correlation tomography of breast tumors.Appl Opt. 2015 Oct 10;54(29):8808-16. doi: 10.1364/AO.54.008808. Appl Opt. 2015. PMID: 26479823 Free PMC article.
-
Instrumentation in Diffuse Optical Imaging.Photonics. 2014 Mar 20;1(1):9-32. doi: 10.3390/photonics1010009. Photonics. 2014. PMID: 24860804 Free PMC article.
-
The effect of temporal impulse response on experimental reduction of photon scatter in time-resolved diffuse optical tomography.Phys Med Biol. 2013 Jan 21;58(2):335-49. doi: 10.1088/0031-9155/58/2/335. Epub 2012 Dec 21. Phys Med Biol. 2013. PMID: 23257349 Free PMC article.
-
Efficient numerical modelling of time-domain light propagation in curved 3D absorbing and scattering media with finite differences.Biomed Opt Express. 2021 Feb 16;12(3):1422-1436. doi: 10.1364/BOE.413854. eCollection 2021 Mar 1. Biomed Opt Express. 2021. PMID: 33796363 Free PMC article.
-
Non-contact small animal fluorescence imaging system for simultaneous multi-directional angular-dependent data acquisition.Biomed Opt Express. 2014 Jun 18;5(7):2301-16. doi: 10.1364/BOE.5.002301. eCollection 2014 Jul 1. Biomed Opt Express. 2014. PMID: 25071965 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources