Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Sep 1;53(7):765-8.
doi: 10.1258/ar.2012.120105. Epub 2012 Jul 3.

Clinical usefulness of adjusted D-dimer cut-off values to exclude pulmonary embolism in a community hospital emergency department patient population

Affiliations

Clinical usefulness of adjusted D-dimer cut-off values to exclude pulmonary embolism in a community hospital emergency department patient population

Josephina A Vossen et al. Acta Radiol. .

Abstract

Background: Plasma D-dimer measurement is used in the assessment of the clinical probability of pulmonary embolism (PE), in order to minimize the requirement for pulmonary computed tomography angiography (CTA).

Purpose: To evaluate whether doubling the threshold value of serum D-dimer from 500 μg/L to 1000 μg/L could safely reduce utilization of pulmonary CTA to exclude PE in our emergency department patient population.

Material and methods: Emergency department patients evaluated for PE with a quantitative D-dimer assay and pulmonary CTA were eligible for inclusion. D-dimer values were retrospectively collected in all included patients. Pulmonary CT angiograms were reviewed and scored as positive or negative for PE. Receiver-operating characteristic (ROC) analysis was used to determine the accuracy of quantitative D-dimer measurements in differentiating between positive and negative PE patients as per CTA.

Results: A total of 237 consecutive patients underwent pulmonary CTA and had a D-dimer measurement performed. Median D-dimer level was 1007 μg/L and in 11 (5%) patients the pulmonary CT CTA was positive for PE. The ROC curve showed an area under the curve (AUC) of 0.91 (P < 0.0001). Increasing the D-dimer threshold value of 500 μg/L to 1000 μg/L increased the specificity from 8% to 52% without changing the sensitivity.

Conclusion: Adjusting the D-dimer cut-off value for the emergency department community population and patient age increases the yield and specificity of the ELISA D-dimer assay for the exclusion of PE without reducing sensitivity.

PubMed Disclaimer

MeSH terms