Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Nov;31(11):1151-7.
doi: 10.1016/j.healun.2012.05.004. Epub 2012 Jul 4.

Continuous-flow devices and percutaneous site infections: clinical outcomes

Affiliations

Continuous-flow devices and percutaneous site infections: clinical outcomes

Daniel J Goldstein et al. J Heart Lung Transplant. 2012 Nov.

Abstract

Background: Although continuous-flow left ventricular assist device (LVAD) support has become standard therapy, the complexities of device and patient management remain a challenge. In particular, percutaneous site infections (PSI) are a serious complication during the post-implant course. We sought to study the incidence, risk factors, and clinical effect of PSI.

Methods: Data were obtained from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Registry. All adult patients who received a primary intracorporeal continuous flow LVAD between June 2006 and September 2010 were included. Descriptive statistics, Kaplan-Meier depictions, and multivariable analysis in the parametric hazard domain were used for statistical analysis.

Results: A total of 239 PSIs were documented in 197 of 2,006 recipients (9.8%) of a continuous-flow LVAD. Mean follow-up was 8.1 months. Mean time to development of a PSI was 6.6 months. At 1 year after implant, nearly 19% of continuous-flow LVAD recipients developed a PSI. Multivariate analysis showed younger age (hazard ratio, 1.20; p < 0.0001) was the only factor predicting a PSI. Continuous-flow LVAD recipients who did not develop a PSI had improved survival (p = 0.004). Twenty-three patients died after development of a PSI. Sepsis was the most common cause of death (26.1%).

Conclusions: PSIs occur in approximately 19% of continuous-flow LVAD recipients by 12 months after implant. Young age is the only predictor of PSI. Importantly, development of a PSI adversely affects survival. Efforts to enhance driveline integration and to develop future totally implantable systems are warranted.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources