Linear variable optical filter-based ultraviolet microspectrometer
- PMID: 22772102
- DOI: 10.1364/AO.51.004308
Linear variable optical filter-based ultraviolet microspectrometer
Abstract
An IC-compatible linear variable optical filter (LVOF) for application in the UV spectral range between 310 and 400 nm has been fabricated using resist reflow and an optimized dry-etching. The LVOF is mounted on the top of a commercially available CMOS camera to result in a UV microspectrometer. A special calibration technique has been employed that is based on an initial spectral measurement on a xenon lamp. The image recorded on the camera during calibration is used in a signal processing algorithm to reconstruct the spectrum of the mercury lamp and the calibration data is subsequently used in UV spectral measurements. Experiments on a fabricated LVOF-based microspectrometer with this calibration approach implemented reveal a spectral resolution of 0.5 nm.
Similar articles
-
Design and implementation of a sub-nm resolution microspectrometer based on a Linear-Variable Optical Filter.Opt Express. 2012 Jan 2;20(1):489-507. doi: 10.1364/OE.20.000489. Opt Express. 2012. PMID: 22274371
-
High resolution on-chip spectroscopy based on miniaturized microdonut resonators.Opt Express. 2011 Jun 20;19(13):12356-64. doi: 10.1364/OE.19.012356. Opt Express. 2011. PMID: 21716473
-
High precision wavelength estimation method for integrated optics.Opt Express. 2013 Jul 15;21(14):17042-52. doi: 10.1364/OE.21.017042. Opt Express. 2013. PMID: 23938552
-
Microspectrometer based on holographically recorded diffractive elements using supplementary holograms.Opt Express. 2008 Aug 4;16(16):12239-50. doi: 10.1364/oe.16.012239. Opt Express. 2008. PMID: 18679501
-
The Erlangen micro-lightguide spectrophotometer EMPHO I.Phys Med Biol. 1989 Dec;34(12):1883-900. doi: 10.1088/0031-9155/34/12/011. Phys Med Biol. 1989. PMID: 2694193 Review.
Cited by
-
High-sensitivity computational miniaturized terahertz spectrometer using a plasmonic filter array and a modified multilayer residual CNN.Nanophotonics. 2023 Nov 2;12(23):4375-4385. doi: 10.1515/nanoph-2023-0581. eCollection 2023 Nov. Nanophotonics. 2023. PMID: 39634719 Free PMC article.
-
SiNx/SiO2-Based Fabry-Perot Interferometer on Sapphire for Near-UV Optical Gas Sensing of Formaldehyde in Air.Sensors (Basel). 2024 Jun 3;24(11):3597. doi: 10.3390/s24113597. Sensors (Basel). 2024. PMID: 38894388 Free PMC article.
-
Miniaturizing color-sensitive photodetectors via hybrid nanoantennas toward submicrometer dimensions.Sci Adv. 2022 Nov 25;8(47):eadd3868. doi: 10.1126/sciadv.add3868. Epub 2022 Nov 23. Sci Adv. 2022. PMID: 36417508 Free PMC article.
-
Static hyperspectral fluorescence imaging of viscous materials based on a linear variable filter spectrometer.Sensors (Basel). 2013 Sep 23;13(9):12687-97. doi: 10.3390/s130912687. Sensors (Basel). 2013. PMID: 24064604 Free PMC article.
-
Compact characterization of liquid absorption and emission spectra using linear variable filters integrated with a CMOS imaging camera.Sci Rep. 2016 Jul 8;6:29117. doi: 10.1038/srep29117. Sci Rep. 2016. PMID: 27389070 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources