Abstract
The full Mueller matrix for a Spectralon white reflectance standard was measured in the incidence plane, to obtain the polarization state of the scattered light for different angles of illumination. The experimental setup was a Mueller matrix ellipsometer, by which measurements were performed for scattering angles measured relative to the normal of the Spectralon surface from -90° to 90° sampled at every 2.5° for an illumination wavelength of 532 nm. Previously, the polarization of light scattered from Spectralon white reflectance standards was measured only for four of the elements of the Muller matrix. As in previous investigations, the reflection properties of the Spectralon white reflectance standard was found to be close to those of a Lambertian surface for small scattering and illumination angles. At large scattering and illumination angles, all elements of the Mueller matrix were found to deviate from those of a Lambertian surface. A simple empirical model with only two parameters, was developed, and used to simulate the measured results with fairly good accuracy.
Similar articles
-
Bidirectional reflectance distribution function of Spectralon white reflectance standard illuminated by incoherent unpolarized and plane-polarized light.Appl Opt. 2011 Jun 1;50(16):2431-42. doi: 10.1364/AO.50.002431. Appl Opt. 2011. PMID: 21629324
-
Mueller matrix measurements of algae with different shape and size distributions.Appl Opt. 2011 Sep 10;50(26):5149-57. doi: 10.1364/AO.50.005149. Appl Opt. 2011. PMID: 21946997
-
Parametric model of the Mueller matrix of a Spectralon white reflectance standard deduced by polar decomposition techniques.Opt Express. 2013 Jul 29;21(15):18509-24. doi: 10.1364/OE.21.018509. Opt Express. 2013. PMID: 23938723
-
Comprehensive polarimetric analysis of Spectralon white reflectance standard in a wide visible range.Appl Opt. 2013 Aug 20;52(24):6051-62. doi: 10.1364/AO.52.006051. Appl Opt. 2013. PMID: 24085010
-