Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences
- PMID: 22778566
- PMCID: PMC3384826
- DOI: 10.3348/kjr.2012.13.4.443
Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences
Abstract
Objective: To compare the image quality of volume isotropic turbo spin echo acquisition (VISTA) imaging method with that of the three-dimensional (3D) isotropic fast field echo (FFE) imaging method applied for ankle joint imaging.
Materials and methods: MR imaging of the ankles of 10 healthy volunteers was performed with VISTA and 3D FFE sequences by using a 3.0 T machine. Two radiologists retrospectively assessed the tissue contrast between fluid and cartilage (F-C), and fluid and the Achilles tendon (F-T) with use of a 4-point scale. For a quantitative analysis, signal-to-noise ratio (SNR) was obtained by imaging phantom, and the contrast ratios (CRs) were calculated between F-T and F-C. Statistical analyses for differences in grades of tissue contrast and CRs were performed.
Results: VISTA had significantly superior grades in tissue contrast of F-T (p = 0.001). Results of 3D FFE had superior grades in tissue contrast of F-C, but these result were not statistically significant (p = 0.157). VISTA had significantly superior CRs in F-T (p = 0.002), and 3D FFE had superior CRs in F-C (p = 0.003). The SNR of VISTA was higher than that of 3D FFE (49.24 vs. 15.94).
Conclusion: VISTA demonstrates superior tissue contrast between fluid and the Achiles tendon in terms of quantitative and qualitative analysis, while 3D FFE shows superior tissue contrast between fluid and cartilage in terms of quantitative analysis.
Keywords: 3D isotropic imaging; Ankle; Cartilage; MRI; Tendon.
Figures


Similar articles
-
3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.Acta Radiol. 2011 Dec 1;52(10):1119-24. doi: 10.1258/ar.2011.110328. Acta Radiol. 2011. PMID: 22144425
-
Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo.Acta Radiol. 2013 Apr 1;54(3):284-91. doi: 10.1258/ar.2012.120475. Epub 2013 Jan 14. Acta Radiol. 2013. PMID: 23319720
-
Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury.Clin Radiol. 2016 Apr;71(4):349-55. doi: 10.1016/j.crad.2015.12.007. Epub 2016 Jan 14. Clin Radiol. 2016. PMID: 26774370
-
3D isotropic MRI of ankle: review of literature with comparison to 2D MRI.Skeletal Radiol. 2024 May;53(5):825-846. doi: 10.1007/s00256-023-04513-2. Epub 2023 Nov 18. Skeletal Radiol. 2024. PMID: 37978990 Review.
-
Routine 3D magnetic resonance imaging of joints.J Magn Reson Imaging. 2011 Apr;33(4):758-71. doi: 10.1002/jmri.22342. J Magn Reson Imaging. 2011. PMID: 21448939 Free PMC article. Review.
Cited by
-
Chronic ankle instability: a cadaveric anatomical and 3D high-resolution MRI study for surgical reconstruction procedures.Insights Imaging. 2024 Oct 14;15(1):249. doi: 10.1186/s13244-024-01824-3. Insights Imaging. 2024. PMID: 39400621 Free PMC article.
-
Automatic segmentation of human knee anatomy by a convolutional neural network applying a 3D MRI protocol.BMC Musculoskelet Disord. 2023 Jan 18;24(1):41. doi: 10.1186/s12891-023-06153-y. BMC Musculoskelet Disord. 2023. PMID: 36650496 Free PMC article.
References
-
- Jung JY, Yoon YC, Kwon JW, Ahn JH, Choe BK. Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences. Radiology. 2009;253:780–787. - PubMed
-
- Notohamiprodjo M, Horng A, Pietschmann MF, Müller PE, Horger W, Park J, et al. MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence. Invest Radiol. 2009;44:585–597. - PubMed
-
- Gold GE, Busse RF, Beehler C, Han E, Brau AC, Beatty PJ, et al. Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. AJR Am J Roentgenol. 2007;188:1287–1293. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials