Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Dec;28(12):2659-67.
doi: 10.1128/jcm.28.12.2659-2667.1990.

Polymerase chain reaction for detection of adenoviruses in stool samples

Affiliations

Polymerase chain reaction for detection of adenoviruses in stool samples

A Allard et al. J Clin Microbiol. 1990 Dec.

Erratum in

Abstract

The usefulness of the polymerase chain reaction (PCR) method for diagnosing adenovirus infections was investigated. Several primers, including primers specific for the hexon-coding region and for enteric adenovirus types 40 and 41, were evaluated. The PCR method was validated against cell culturing in routine diagnostic work and against restriction enzyme analysis of viral DNA. Sixty diagnostic specimens were selected for evaluation by the PCR method. Twenty of the 60 specimens were found positive on the basis of cytopathic effects and latex agglutination (Adenolex [Orion Diagnostica, Helsinki, Finland]), and 16 were identified and typed as adenoviruses by polyacrylamide gel electrophoresis. PCR was performed on all 60 specimens in parallel directly on diluted stool samples and on viral DNA extracted from cells inoculated with the same stool samples. When the general hexon primers were used 51 of the 60 specimens from infected cell cultures were found positive by PCR, whereas only 13 specimens were found positive when PCR was performed directly on stool samples. With the use of selective primers for enteric adenoviruses 16 of the 60 cell cultures were found to exhibit amplification products by PCR, whereas 4 were detected in stool samples. None of the 60 specimens were found positive by PCR when an adenovirus type 40-specific primer pair was used. PCR was found to be a fast, sensitive, and reliable method for the detection of adenoviruses in diarrheal disease, provided the amplifications were performed directly on diluted stool samples.

PubMed Disclaimer

References

    1. J Clin Microbiol. 1984 Nov;20(5):1008-9 - PubMed
    1. J Biol Chem. 1984 Nov 25;259(22):13976-9 - PubMed
    1. J Virol. 1985 Apr;54(1):145-50 - PubMed
    1. J Med Virol. 1985 Sep;17(1):19-27 - PubMed
    1. J Clin Microbiol. 1985 Dec;22(6):934-9 - PubMed

Publication types