Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Feb;34(2):220-5.
doi: 10.1007/s00246-012-0413-6. Epub 2012 Jul 18.

Percutaneous atrial septal defect closure in infants and toddlers: predictors of success

Affiliations
Comparative Study

Percutaneous atrial septal defect closure in infants and toddlers: predictors of success

Christopher J Petit et al. Pediatr Cardiol. 2013 Feb.

Abstract

Device closure of atrial septal defect (ASD) is commonly performed in older children and adults. Infants and toddlers (age <4 years) are seldom referred for ASD closure due to size constraints. However, in many cases device ASD closure can be performed in this population. Between 2002 and 2012, 61 infants and toddlers were taken to the catheterization laboratory at our institution for ASD closure. Precatheterization transthoracic echocardiograms, intracatheterization transesophageal echocardiograms, and catheterization reports were reviewed. Fifty-three infants and toddlers presented for percutaneous ASD occlusion. Forty-eight (79 %) underwent successful closure, and 13 were referred for surgery without device attempt (n = 8) or after unsuccessful device occlusion (n = 4). Median age and weight at time of ASD closure were 2.99 years (range 0.3-3.8) and 11.7 kg (range 3.7-16.5). The device-to-septal length ratio was 0.81 (range 0.44-1.03). The 12 unsuccessful cases occurred in patients with larger defects (ASD diameter 17.5 ± 6.1 vs. 12.1 ± 4.2, p < 0.01). Deficient rims (absent or ≤ 4 mm) were seen in 9 of 12 (75 %) unsuccessful cases and in 19 of 41 (46 %) successful cases (p = 0.12). Multivariate analysis showed that patient size and ASD size were not independently associated with procedural success but that ASD size-to-patient weight ratio <1.2 (hazard ratio 9.5 [range1.7-17]) was associated with successful ASD closure. ASD device occlusion can be safely achieved in small children. An ASD size-to-patient weight ratio >1.2, not absolute patient weight or age, is associated with failure of the percutaneous approach. The midterm outcomes in these young patients are excellent.

PubMed Disclaimer

References

    1. Echocardiography. 2009 Nov;26(10):1146-52 - PubMed
    1. J Am Coll Cardiol. 2003 Jul 16;42(2):241-5 - PubMed
    1. Catheter Cardiovasc Interv. 2007 Feb 15;69(3):447-52 - PubMed
    1. Ann Thorac Surg. 2008 Nov;86(5):1584-90; discussion 1590-1 - PubMed
    1. Pediatr Cardiol. 2009 Oct;30(7):888-92 - PubMed

Publication types

LinkOut - more resources