A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards
- PMID: 22809908
- DOI: 10.1097/CCM.0b013e318255d9a0
A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards
Abstract
Objectives: Deteriorating ward patients are at increased risk. Electronic automated advisory vital signs monitors may help identify such patients and improve their outcomes.
Setting: A total of 349 beds, in 12 general wards in ten hospitals in the United States, Europe, and Australia.
Patients: Cohort of 18,305 patients.
Design: Before-and-after controlled trial.
Intervention: We deployed electronic automated advisory vital signs monitors to assist in the acquisition of vital signs and calculation of early warning scores. We assessed their effect on frequency, type, and treatment of rapid response team calls; survival to hospital discharge or to 90 days for rapid response team call patients; overall type and number of serious adverse events and length of hospital stay.
Measurements and main results: We studied 9,617 patients before (control) and 8,688 after (intervention) deployment of electronic automated advisory vital signs monitors. Among rapid response team call patients, intervention was associated with an increased proportion of calls secondary to abnormal respiratory vital signs (from 21% to 31%; difference [95% confidence interval] 9.9 [0.1-18.5]; p=.029). Survival immediately after rapid response team treatment and survival to hospital discharge or 90 days increased from 86% to 92% (difference [95% confidence interval] 6.3 [0.0-12.6]; p=.04). Intervention was also associated with a decrease in median length of hospital stay in all patients (unadjusted p<.0001; adjusted p=.09) and more so in U.S. patients (from 3.4 to 3.0 days; unadjusted p<.0001; adjusted ratio [95% confidence interval] 1.03 [1.00-1.06]; p=.026). The time required to complete and record a set of vital signs decreased from 4.1±1.3 mins to 2.5±0.5 mins (difference [95% confidence interval] 1.6 [1.4-1.8]; p<.0001).
Conclusions: Deployment of electronic automated advisory vital signs monitors was associated with an improvement in the proportion of rapid response team-calls triggered by respiratory criteria, increased survival of patients receiving rapid response team calls, and decreased time required for vital signs measurement and recording (NCT01197326).
Comment in
-
Generation of early warnings with smart monitors: the future is all about getting back to the basics!Crit Care Med. 2012 Aug;40(8):2509-11. doi: 10.1097/CCM.0b013e31825adc46. Crit Care Med. 2012. PMID: 22809927 No abstract available.
Similar articles
-
Abnormal vital signs are associated with an increased risk for critical events in US veteran inpatients.Resuscitation. 2009 Nov;80(11):1264-9. doi: 10.1016/j.resuscitation.2009.08.012. Epub 2009 Sep 9. Resuscitation. 2009. PMID: 19744762
-
A prospective controlled trial of the effect of a multi-faceted intervention on early recognition and intervention in deteriorating hospital patients.Resuscitation. 2010 Jun;81(6):658-66. doi: 10.1016/j.resuscitation.2010.03.001. Epub 2010 Apr 7. Resuscitation. 2010. PMID: 20378235 Clinical Trial.
-
Factors associated with delayed activation of medical emergency team and excess mortality: an Utstein-style analysis.Resuscitation. 2013 Feb;84(2):173-8. doi: 10.1016/j.resuscitation.2012.09.021. Epub 2012 Sep 23. Resuscitation. 2013. PMID: 23009981
-
The Afferent Limb of Rapid Response Systems: Continuous Monitoring on General Care Units.Crit Care Clin. 2018 Apr;34(2):189-198. doi: 10.1016/j.ccc.2017.12.001. Epub 2018 Jan 8. Crit Care Clin. 2018. PMID: 29482899 Review.
-
Early warning score challenges and opportunities in the care of deteriorating patients .Dan Med J. 2018 Feb;65(2):B5439. Dan Med J. 2018. PMID: 29393044 Review.
Cited by
-
Causes, Diagnostic Testing, and Treatments Related to Clinical Deterioration Events Among High-Risk Ward Patients.Crit Care Explor. 2024 Oct 1;6(10):e1161. doi: 10.1097/CCE.0000000000001161. eCollection 2024 Oct 1. Crit Care Explor. 2024. PMID: 39356139 Free PMC article.
-
Remote Monitoring by ViQtor Upon Implementation on a Surgical Department (REQUEST-Trial): Protocol for a Prospective Implementation Study.JMIR Res Protoc. 2025 Jul 3;14:e70707. doi: 10.2196/70707. JMIR Res Protoc. 2025. PMID: 40608408 Free PMC article.
-
Temporal distribution of instability events in continuously monitored step-down unit patients: implications for Rapid Response Systems.Resuscitation. 2015 Apr;89:99-105. doi: 10.1016/j.resuscitation.2015.01.015. Epub 2015 Jan 28. Resuscitation. 2015. PMID: 25637693 Free PMC article.
-
Real-Time Risk Prediction on the Wards: A Feasibility Study.Crit Care Med. 2016 Aug;44(8):1468-73. doi: 10.1097/CCM.0000000000001716. Crit Care Med. 2016. PMID: 27075140 Free PMC article.
-
Tele-Rapid Response Team (Tele-RRT): The effect of implementing patient safety network system on outcomes of medical patients-A before and after cohort study.PLoS One. 2022 Nov 22;17(11):e0277992. doi: 10.1371/journal.pone.0277992. eCollection 2022. PLoS One. 2022. PMID: 36413553 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical