Objective: To examine if liver stiffness measured by magnetic resonance elastography (MRE) is a risk factor for hepatocellular carcinoma (HCC) in patients with chronic liver disease.
Methods: By reviewing the records of magnetic resonance (MR) examinations performed at our institution, we selected 301 patients with chronic liver disease who did not have a previous medical history of HCC. All patients underwent MRE and gadoxetic acid-enhanced MR imaging. HCC was identified on MR images in 66 of the 301 patients, who were matched to controls from the remaining patients without HCC according to age. MRE images were obtained by visualising elastic waves generated in the liver by pneumatic vibration transferred via a cylindrical passive driver. Risk factors of HCC development were determined by the odds ratio with logistic regression analysis; gender and liver stiffness by MRE and serum levels of aspartate transferase, alanine transferase, alpha-fetoprotein, and protein induced by vitamin K absence-II.
Results: Multivariate analysis revealed that only liver stiffness by MRE was a significant risk factor for HCC with an odds ratio (95 % confidence interval) of 1.38 (1.05-1.84).
Conclusion: Liver stiffness measured by MRE is an independent risk factor for HCC in patients with chronic liver disease.
Comment in
-
[Stiffness of the liver and HCC risk factor identification].Rofo. 2013 Nov;185(11):1026-7. Rofo. 2013. PMID: 24308048 German. No abstract available.
Similar articles
-
Magnetic resonance elastography can predict development of hepatocellular carcinoma with longitudinally acquired two-point data.Eur Radiol. 2019 Feb;29(2):1013-1021. doi: 10.1007/s00330-018-5640-7. Epub 2018 Jul 24. Eur Radiol. 2019. PMID: 30043162
-
Liver stiffness measured by MR elastography is a predictor of early HCC recurrence after treatment.Eur Radiol. 2020 Aug;30(8):4182-4192. doi: 10.1007/s00330-020-06792-y. Epub 2020 Mar 18. Eur Radiol. 2020. PMID: 32189053
-
Association between non-hypervascular hypointense nodules on gadoxetic acid-enhanced MRI and liver stiffness or hepatocellular carcinoma.Eur J Radiol. 2017 Oct;95:362-369. doi: 10.1016/j.ejrad.2017.08.036. Epub 2017 Aug 31. Eur J Radiol. 2017. PMID: 28987693
-
Clinical application of Magnetic resonance elastography in hepatocellular carcinoma: from diagnosis to prognosis.Ann Hepatol. 2023 Mar-Apr;28(2):100889. doi: 10.1016/j.aohep.2022.100889. Epub 2022 Dec 23. Ann Hepatol. 2023. PMID: 36572210 Review.
-
Magnetic Resonance Elastography of the Brain.Magn Reson Imaging Clin N Am. 2021 Nov;29(4):617-630. doi: 10.1016/j.mric.2021.06.011. Magn Reson Imaging Clin N Am. 2021. PMID: 34717849 Review.
Cited by
-
Liver stiffness measured by magnetic resonance elastography in early recurrence of hepatocellular carcinoma after treatment: A protocol for systematic review and meta analysis.Medicine (Baltimore). 2021 Jun 11;100(23):e26183. doi: 10.1097/MD.0000000000026183. Medicine (Baltimore). 2021. PMID: 34115001 Free PMC article.
-
The role of sonoelastography in planning percutaneous biopsy of soft tissue tumours.Ultrasound. 2015 Nov;23(4):212-5. doi: 10.1177/1742271X15608214. Epub 2015 Sep 28. Ultrasound. 2015. PMID: 27433261 Free PMC article.
-
Quantitative Elastography Methods in Liver Disease: Current Evidence and Future Directions.Radiology. 2018 Mar;286(3):738-763. doi: 10.1148/radiol.2018170601. Radiology. 2018. PMID: 29461949 Free PMC article. Review.
-
Magnetic resonance elastography of the liver: everything you need to know to get started.Abdom Radiol (NY). 2022 Jan;47(1):94-114. doi: 10.1007/s00261-021-03324-0. Epub 2021 Nov 1. Abdom Radiol (NY). 2022. PMID: 34725719 Free PMC article. Review.
-
Impact of axisymmetric deformation on MR elastography of a nonlinear tissue-mimicking material and implications in peri-tumour stiffness quantification.PLoS One. 2021 Jul 9;16(7):e0253804. doi: 10.1371/journal.pone.0253804. eCollection 2021. PLoS One. 2021. PMID: 34242296 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical