Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Dec;29(12):3325-34.
doi: 10.1007/s11095-012-0824-3. Epub 2012 Jul 20.

Penetration of fluorescein across the rabbit cornea from the endothelial surface

Affiliations

Penetration of fluorescein across the rabbit cornea from the endothelial surface

Chhavi Gupta et al. Pharm Res. 2012 Dec.

Abstract

Purpose: To model the kinetics of penetration of fluorescein across the cornea from the endothelial surface.

Methods: Rabbit corneas mounted in vitro were exposed to fluorescein at their endothelial surface. Trans-corneal fluorescence were acquired periodically for 6 h using a custom-built confocal microfluorometer. The profiles were then employed to fit a kinetic model for calculation of permeability and diffusion coefficients across the cellular layers and stroma, respectively.

Results: At the endothelium-stroma and stroma-epithelium interfaces, the fluorescence profile exhibited sudden jumps. In each case, the fluorescence was higher at the stroma, indicating reduced partitioning of the dye into the lipid-rich cellular layers. The stroma did not swell significantly until 180 min of perfusion. The fluorescence profiles reached a pseudo-steady state at ~6 h. A transport model, which included convective and diffusive fluxes into the stroma, showed a good fit to the trans-corneal profiles at different time points. The estimated permeability coefficients for the cellular layers were close to the values reported previously, but the diffusion coefficient of fluorescein in the stroma was found to be smaller than the values obtained previously using Ussing chambers.

Conclusions: The penetration of fluorescein could be modeled accurately by a combination of diffusion and convection.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Exp Eye Res. 1985 Sep;41(3):383-90 - PubMed
    1. Jpn J Ophthalmol. 1983;27(3):421-33 - PubMed
    1. Q J Exp Physiol. 1987 Oct;72(4):409-37 - PubMed
    1. Optom Vis Sci. 2010 Apr;87(4):E239-54 - PubMed
    1. Exp Eye Res. 1987 Jan;44(1):73-87 - PubMed

Publication types

LinkOut - more resources