One-bottle self-etching adhesives applied to dentine air-abraded using bioactive glasses containing polyacrylic acid: an in vitro microtensile bond strength and confocal microscopy study

Affiliations

One-bottle self-etching adhesives applied to dentine air-abraded using bioactive glasses containing polyacrylic acid: an in vitro microtensile bond strength and confocal microscopy study

Salvatore Sauro et al. J Dent. 2012 Nov.

Abstract

Objectives: The aim of this study was to test the microtensile bond strength (μTBS) of two "simplified" self-etching adhesives bonded to air-abraded dentine using experimental bioactive glass powders containing polyacrylic acid.

Methods: Sound dentine specimens were air-abraded using a pure Bioglass 45S5 (Bioglass) powder or two Bioglass powders containing different concentration of polyacrylic acid (PAA: 15 wt% or 40 wt%). The bonding procedures were accomplished by the application of two self-etching adhesives (CS3: Clearfil S3 Bond; Kuraray, Osaka, Japan or GB: G Bond; GC Ltd. Tokyo, Japan). The resin-bonded specimens were cut in beams (0.9 mm(2)) and the μTBS testing was performed after 24h or 6months of phosphate buffer solution (PBS) storage. The results were statistically analysed by three-way ANOVA and Student-Newman-Keuls test used (α=0.05). Further bonded-dentine specimens were used for the confocal microscopy interfacial characterisation and micropermeability analysis.

Results: The CS3 adhesive system achieved higher μTBS than those attained in the specimens bonded with GB both after 24h and 6 months of PBS storage. The CLSM analysis performed after 6months of PBS storage indicated severe micropermeability within the bonded-dentine interfaces created using GB applied onto dentine air-abraded with Bioglass/PAA-15 and Bioglass/PAA-40. Conversely, CS3 exhibited no dye penetration (micropermeability) at the resin-dentine interface.

Conclusion: It is possible to affirm that air-abrasion procedures performed using pure Bioglass or Bioglass containing 15 wt% PAA do not interfere with the immediate bonding performance of self-etching adhesives. However, the durability of the bonded-dentine interfaces created subsequent air-abrasion procedures using bioactive glasses will depend also upon the chemical composition of the self-etch adhesive systems.