Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Feb;29(2):355-61.
doi: 10.1007/s10554-012-0099-0. Epub 2012 Jul 24.

Is contrast-enhanced cardiac magnetic resonance imaging at 3 T superior to 1.5 T for detection of coronary artery disease?

Affiliations
Comparative Study

Is contrast-enhanced cardiac magnetic resonance imaging at 3 T superior to 1.5 T for detection of coronary artery disease?

Thomas Walcher et al. Int J Cardiovasc Imaging. 2013 Feb.

Abstract

The aim is to compare a compiled clinical routine cardiac magnetic resonance (CMR) imaging protocol performed at both 1.5 and 3 T in patients with suspected coronary artery disease (CAD) undergoing coronary X-ray angiography. CMR including adenosine perfusion and late gadolinium enhancement (LGE) at 1.5 T has been established for noninvasive detection of relevant CAD. However, little is known about the potential advantages of 3 T to detect CAD. Fifty-two evaluable patients (62.3 ± 10.2 years) were included into the study. All patients were scanned at both 1.5 and 3 T including adenosine stress and rest perfusion, and LGE imaging. CMR images were analyzed by two blinded readers in consensus. X-Ray angiography served as the reference method. A significant CAD was diagnosed by quantitative coronary analysis. Diagnostic accuracy of the combined analysis of perfusion and LGE imaging yielded better values at 1.5 and 3 T than the analysis of perfusion images alone. Specificity and sensitivity at 3 T was superior to 1.5 T in detecting coronary stenoses ≥50 % (90 vs. 75 % and 84.4 vs. 75 %) and ≥70 % (88 vs. 80 % and 96.3 vs. 88.9 %). This study showed that CMR at 3 T in a routine clinical setting is superior to 1.5 T in detection of significant CAD. 3 T might become the preferred CMR field strength for evaluation of CAD in clinical practice.

PubMed Disclaimer

References

    1. Circulation. 1998 May 12;97(18):1837-47 - PubMed
    1. Circulation. 2001 May 8;103(18):2230-5 - PubMed
    1. Circulation. 1999 May 4;99(17):2345-57 - PubMed
    1. J Magn Reson. 1997 Mar;125(1):65-71 - PubMed
    1. J Cardiovasc Magn Reson. 2008 Oct 17;10:45 - PubMed

Publication types

MeSH terms

LinkOut - more resources