Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Oct;36(10):931-5.
doi: 10.1111/j.1525-1594.2012.01494.x. Epub 2012 Jul 27.

Comparison of the effects of three cell saver devices on erythrocyte function during cardiopulmonary bypass procedure--a pilot study

Affiliations
Randomized Controlled Trial

Comparison of the effects of three cell saver devices on erythrocyte function during cardiopulmonary bypass procedure--a pilot study

Xiaohua Wang et al. Artif Organs. 2012 Oct.

Abstract

Cell salvage devices are routinely used to process red blood cells (RBCs) shed during cardiac surgery. The purpose of this study was to evaluate three commercially available cell saver (CS) devices in terms of erythrocyte function and the quality of washed RBCs during cardiopulmonary bypass (CPB). Thirty patients undergoing CPB were randomly allocated to three CS devices: Group C (Cell Saver 5+; Haemonetics, n = 10), Group M (autolog; Medtronic, n = 10), and Group F (CATS; Fresenius HemoCare, n = 10). Blood samples were collected from reservoirs and transfusion bags. Reservoirs and washed RBCs were analyzed for erythrocyte aggregation index, deformation index (DI) and hematocrit viscosity, 2,3-diphosphoglycerate (2,3-DPG), hematocrit (Hct), hemoglobin (Hb), free Hb removal (ΔfHb), glucose (Glu), lactate (Lac), and blood urea nitrogen. After processing, Groups C (P = 0.026) and M (P = 0.032) had relatively higher erythrocyte DI compared with Group F. Group C had lower Δ2,3-DPG compared with Groups M (P = 0.001) and F (P = 0.001). Group F provided the maximum concentration of Hct (P = 0.021; 0.046) and Hb (P = 0.008; 0.013). In addition, Groups C (P = 0.035) and M (P = 0.038) had a higher removal of fHb (ΔfHb), differing significantly with Group F. In conclusion, CS devices use the same theory of centrifugation; however, based on different designs, the function of the washed erythrocyte and undesirable content removal efficiency differs widely from one device to another.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources