Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Sep;82(1):19-24.
doi: 10.1016/j.jhin.2012.06.007. Epub 2012 Jul 28.

Multidrug-resistant Pseudomonas aeruginosa outbreaks in two hospitals: association with contaminated hospital waste-water systems

Affiliations

Multidrug-resistant Pseudomonas aeruginosa outbreaks in two hospitals: association with contaminated hospital waste-water systems

A S Breathnach et al. J Hosp Infect. 2012 Sep.

Abstract

Background: Multidrug-resistant Pseudomonas aeruginosa (MDR-P) expressing VIM-metallo-beta-lactamase is an emerging infection control problem. The source of many such infections is unclear, though there are reports of hospital outbreaks of P. aeruginosa related to environmental contamination, including tap water.

Aim: We describe two outbreaks of MDR-P, sensitive only to colistin, in order to highlight the potential for hospital waste-water systems to harbour this organism.

Methods: The outbreaks were investigated by a combination of descriptive epidemiology, inspection and microbiological sampling of the environment, and molecular strain typing.

Findings: The outbreaks occurred in two English hospitals; each involved a distinct genotype of MDR-P. One outbreak was hospital-wide, involving 85 patients, and the other was limited to four cases in one specialized medical unit. Extensive environmental sampling in each outbreak yielded MDR-P only from the waste-water systems. Inspection of the environment and estates records revealed many factors that may have contributed to contamination of clinical areas, including faulty sink, shower and toilet design, clean items stored near sluices, and frequent blockages and leaks from waste pipes. Blockages were due to paper towels, patient wipes, or improper use of bedpan macerators. Control measures included replacing sinks and toilets with easier-to-clean models less prone to splashback, educating staff to reduce blockages and inappropriate storage, reviewing cleaning protocols, and reducing shower flow rates to reduce flooding. These measures were followed by significant reductions in cases.

Conclusion: The outbreaks highlight the potential of hospital waste systems to act as a reservoir of MDR-P and other nosocomial pathogens.