Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: fundamental concepts and technical developments
- PMID: 22846629
- DOI: 10.1016/j.chroma.2012.07.019
Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: fundamental concepts and technical developments
Abstract
Capillary electrophoresis (CE) hyphenated to electrospray ionization (ESI) mass spectrometry (MS) is a powerful tool for analyzing a wide variety of analytes in different matrices. The major issue with CE-ESI-MS lies in finding a suitable and versatile interface to ensure the best CE and ESI operations. Thus, the development and improvement of CE-ESI-MS interfaces have been the subjects of much research. The first part of the present review focuses on the fundamental aspects of the three steps of the ESI process, i.e., spray formation, droplet evolution, and the production of gas-phase ions. In the second part of the review, the electrochemical reactions involved in the ESI and CE processes and their influences on the sensitivity and performance are discussed in detail. Then, the existing interfaces are divided into two major classes according to their operating flow rate (electrospray vs. nanospray regime). The particular characteristics of these two regimes are discussed by considering their practical impacts on ionization and the MS response. Finally, the current CE-ESI-MS interfaces are summarized, including their major advantages, drawbacks, and fields of application.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry.J Chromatogr A. 2007 Aug 3;1159(1-2):2-13. doi: 10.1016/j.chroma.2007.03.115. Epub 2007 Apr 4. J Chromatogr A. 2007. PMID: 17428492 Review.
-
Study of the electrical connection mechanism of sheathless interface for capillary electrophoresis-electrospray ionization-mass spectrometry.J Mass Spectrom. 2012 Nov;47(11):1429-34. doi: 10.1002/jms.3077. J Mass Spectrom. 2012. PMID: 23147818
-
Alternatives for coupling sequential injection systems to commercial capillary electrophoresis-mass spectrometry equipment.J Chromatogr A. 2006 Sep 15;1127(1-2):278-85. doi: 10.1016/j.chroma.2006.05.077. Epub 2006 Jul 18. J Chromatogr A. 2006. PMID: 16854424
-
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE-ESI-MS coupling.Electrophoresis. 2012 Feb;33(4):552-62. doi: 10.1002/elps.201100461. Electrophoresis. 2012. PMID: 22451047
-
Ionization techniques in capillary electrophoresis-mass spectrometry: principles, design, and application.Mass Spectrom Rev. 2011 Nov-Dec;30(6):1096-120. doi: 10.1002/mas.20313. Epub 2011 Apr 1. Mass Spectrom Rev. 2011. PMID: 21462232 Review.
Cited by
-
Screening of complicated matrixes with paper assisted ultrasonic spray ionization mass spectrometry.J Am Soc Mass Spectrom. 2014 Jun;25(6):935-42. doi: 10.1007/s13361-014-0862-7. Epub 2014 Mar 25. J Am Soc Mass Spectrom. 2014. PMID: 24664810
-
Fluorimetric Analysis of Five Amino Acids in Chocolate: Development and Validation.Molecules. 2021 Jul 16;26(14):4325. doi: 10.3390/molecules26144325. Molecules. 2021. PMID: 34299600 Free PMC article.
-
[Coupling capillary electrophoresis-electrospray ionization mass spectrometry with sheathless interface for drug analysis].Se Pu. 2023 Feb;41(2):160-167. doi: 10.3724/SP.J.1123.2022.07015. Se Pu. 2023. PMID: 36725712 Free PMC article. Chinese.
-
Recent advances in the analysis of therapeutic proteins by capillary and microchip electrophoresis.Anal Methods. 2014 Jul 8;6(15):5427-5449. doi: 10.1039/C4AY00447G. Anal Methods. 2014. PMID: 25126117 Free PMC article.
-
Current Challenges and Future Directions in Peptidomics.Methods Mol Biol. 2024;2758:485-498. doi: 10.1007/978-1-0716-3646-6_26. Methods Mol Biol. 2024. PMID: 38549031
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources