Psychometric evaluation of visual analog scale for the assessment of chronic tinnitus
- PMID: 22846637
- DOI: 10.1044/1059-0889(2012/12-0010)
Psychometric evaluation of visual analog scale for the assessment of chronic tinnitus
Abstract
Purpose: The development of therapeutic interventions for chronic tinnitus requires sensitive and clinically responsive tools to measure treatment-induced changes in tinnitus loudness and annoyance. In this study, the authors evaluated the psychometric properties of patient-reported visual analog scales (VAS) for measuring subjectively perceived tinnitus loudness and annoyance.
Method: The authors analyzed data from a single-blind, randomized, placebo-controlled study of acoustic coordinated reset (CR) neuromodulation in patients with chronic tinnitus (trial registration: "Randomized Evaluation of Sound Evoked Treatment of Tinnitus [RESET] study"; ClinicalTrials.gov identifier: NCT00927121) to assess the reliability, validity, and minimally clinically identifiable difference (MCID) of the VAS loudness and VAS annoyance. The VAS loudness and VAS annoyance were completed at screening, at baseline, and at 5 visits during the 16 weeks of the clinical study. Data were analyzed with respect to test-retest reliability, validity, and MCID.
Results: VAS loudness and VAS annoyance showed good test-retest reliability of .8 and .79, respectively. In terms of convergent validity, VAS loudness and VAS annoyance correlated well with the tinnitus questionnaire at all clinical visits (max r = .67, p < .05). MCID estimates clustered between 10 and 15 points.
Conclusion: VAS loudness and VAS annoyance are valid and effective measurements for capturing reductions in tinnitus severity in patients with chronic tinnitus.
Similar articles
-
[ACOUSTIC CR®-NEUROMODULATION -- FIRST EXPERIENCIES IN HUNGARY WITH A NOVEL METHOD IN THE THERAPY OF CHRONIC SUBJECTIVE TINNITUS].Ideggyogy Sz. 2015 May 30;68(5-6):189-98. Ideggyogy Sz. 2015. PMID: 26182610 Clinical Trial. Hungarian.
-
Validity and reliability study of three tinnitus self-assessment scales: loudness, annoyance and change.Acta Otolaryngol. 2005 Nov;125(11):1184-8. doi: 10.1080/00016480510012282. Acta Otolaryngol. 2005. PMID: 16353397 Clinical Trial.
-
Combination of gaps in noise detection and visual analog scale for measuring tinnitus components in patients treated with repetitive transcranial magnetic stimulation.Auris Nasus Larynx. 2016 Jun;43(3):254-8. doi: 10.1016/j.anl.2015.09.004. Epub 2015 Oct 1. Auris Nasus Larynx. 2016. PMID: 26428287
-
Minimal Clinically Important Difference of Tinnitus Outcome Measurement Instruments-A Scoping Review.J Clin Med. 2023 Nov 15;12(22):7117. doi: 10.3390/jcm12227117. J Clin Med. 2023. PMID: 38002730 Free PMC article.
-
"Measurement" of Tinnitus.Otol Neurotol. 2016 Sep;37(8):e276-85. doi: 10.1097/MAO.0000000000001070. Otol Neurotol. 2016. PMID: 27518136 Review.
Cited by
-
Effectiveness of bimodal auditory and electrical stimulation in patients with tinnitus: A feasibility study.Front Neurosci. 2022 Aug 24;16:971633. doi: 10.3389/fnins.2022.971633. eCollection 2022. Front Neurosci. 2022. PMID: 36090280 Free PMC article.
-
The potential interruptive effect of tinnitus-related distress on attention.Sci Rep. 2020 Jul 17;10(1):11911. doi: 10.1038/s41598-020-68664-1. Sci Rep. 2020. PMID: 32681139 Free PMC article.
-
Repeated sessions of transcranial direct current stimulation for treatment of chronic subjective tinnitus: a pilot randomized controlled trial.Neurol Sci. 2016 Feb;37(2):253-9. doi: 10.1007/s10072-015-2393-9. Epub 2015 Oct 24. Neurol Sci. 2016. PMID: 26498289 Clinical Trial.
-
Is the cochlear implant a successful long-term solution for single-sided deaf and asymmetric hearing-impaired patients?Eur Arch Otorhinolaryngol. 2021 Sep;278(9):3257-3265. doi: 10.1007/s00405-020-06411-y. Epub 2020 Oct 16. Eur Arch Otorhinolaryngol. 2021. PMID: 33067677 Free PMC article.
-
Pilot study of a smartphone-based tinnitus therapy using structured counseling and sound therapy: A multiple-baseline design with ecological momentary assessment.PLOS Digit Health. 2023 Jan 18;2(1):e0000183. doi: 10.1371/journal.pdig.0000183. eCollection 2023 Jan. PLOS Digit Health. 2023. PMID: 36812641 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical