Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study

Affiliations

Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study

Mansour Rismanchian et al. ISRN Dent. 2012.

Abstract

Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α = 0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P = 0.004). None of the histomorphometric values showed significant differences between the two implants (P > 0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Photomicrographs illustrating used to determine bone-to-implant contact ((a) Xive implant and (b) Nisastan implant).
Figure 2
Figure 2
Cross-section of bone-implant surface. Bone trabeculae are in close contact with the implant surface in two groups. (a) Xive implant and (b) Nisastan implant. (Acid fuchsin and toluidine blue, optical microscope; original magnification ×100).

Similar articles

Cited by

References

    1. Aguirre-Zorzano LA, Rodríguez-Andrés C, Estefanía-Fresco R, Fernández-Jiménez A. Immediate temporary restoration of single-tooth implants: prospective clinical study. Medicina Oral, Patologia Oral y Cirugia Bucal. 2011;16(6):e794–e799. - PubMed
    1. Browaeys H, Defrancq J, Dierens MC, et al. A retrospective analysis of early and immediately loaded osseotite implants in cross-arch rehabilitations in edentulous maxillas and mandibles up to 7years. Clinical Implant Dentistry and Related Research. In press. - PubMed
    1. Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scandinavian Journal of Plastic and Reconstructive Surgery. Supplementum. 1977;16:1–132. - PubMed
    1. Chaushu G, Chaushu S, Tzohar A, Dayan D. Immediate loading of single-tooth implants: immediate versus non-immediate implantation. A clinical report. The International Journal of Oral and Maxillofacial Implants. 2001;16(2):267–272. - PubMed
    1. Cornelini R, Cangini F, Covani U, Wilson TG., Jr. Immediate restoration of implants placed into fresh extraction sockets for single-tooth replacement: a prospective clinical study. International Journal of Periodontics and Restorative Dentistry. 2005;25(5):439–447. - PubMed

LinkOut - more resources