MEG versus EEG localization test using implanted sources in the human brain
- PMID: 2285267
- DOI: 10.1002/ana.410280613
MEG versus EEG localization test using implanted sources in the human brain
Abstract
It is believed that the magnetoencephalogram (MEG) localizes an electrical source in the brain to within several millimeters and is therefore more accurate than electroencephalogram (EEG) localization, reported as 20 mm. To test this belief, the localization accuracy of the MEG and EEG were directly compared. The signal source was a dipole at a known location in the brain; this was made by passing a weak current pulse simulating a neural signal through depth electrodes already implanted in patients for seizure monitoring. First, MEGs and EEGs from this dipole were measured at 16 places on the head. Then, computations were performed on the MEG and EEG data separately to determine the apparent MEG and EEG source locations. Finally, these were compared with the actual source location to determine the MEG and EEG localization errors. Measurements were made of four dipoles in each of three patients. After MEGs with weak signals were discounted, the MEG average error of localization was found to be 8 mm, which was worse than expected. The average EEG error was 10 mm, which was better than expected. These results suggest that the MEG offers no significant advantage over the EEG in localizing a focal source. However, this does not diminish other uses of the MEG.
Comment in
-
MEG versus EEG localization test.Ann Neurol. 1991 Aug;30(2):222-4. doi: 10.1002/ana.410300220. Ann Neurol. 1991. PMID: 1897915 No abstract available.
Similar articles
-
Tests of EEG localization accuracy using implanted sources in the human brain.Ann Neurol. 1991 Feb;29(2):132-8. doi: 10.1002/ana.410290204. Ann Neurol. 1991. PMID: 2012383
-
EEG and MEG source analysis of single and averaged interictal spikes reveals intrinsic epileptogenicity in focal cortical dysplasia.Epilepsia. 2004 Jun;45(6):621-31. doi: 10.1111/j.0013-9580.2004.56503.x. Epilepsia. 2004. PMID: 15144427
-
Magnetoencephalography is more successful for screening and localizing frontal lobe epilepsy than electroencephalography.Epilepsia. 2007 Nov;48(11):2139-49. doi: 10.1111/j.1528-1167.2007.01223.x. Epub 2007 Jul 28. Epilepsia. 2007. PMID: 17662061
-
EEG versus MEG localization accuracy: theory and experiment.Brain Topogr. 1991 Winter;4(2):95-103. doi: 10.1007/BF01132766. Brain Topogr. 1991. PMID: 1793693 Review.
-
How can intracranial recordings assist MEG source localization?Neurol Clin Neurophysiol. 2004 Nov 30;2004:86. Neurol Clin Neurophysiol. 2004. PMID: 16012657 Review.
Cited by
-
How to assess the accuracy of volume conduction models? A validation study with stereotactic EEG data.Front Hum Neurosci. 2024 Feb 12;18:1279183. doi: 10.3389/fnhum.2024.1279183. eCollection 2024. Front Hum Neurosci. 2024. PMID: 38410258 Free PMC article.
-
Electrophysiological Neuroimaging using sLORETA Comparing 100 Schizophrenia Patients to 48 Patients with Major Depression.Brain (Bacau). 2014 Dec;5(1-4):16-25. Brain (Bacau). 2014. PMID: 26609423 Free PMC article.
-
Modifications of EEG power spectra in mesial temporal lobe during n-back tasks of increasing difficulty. A sLORETA study.Front Hum Neurosci. 2013 Apr 2;7:109. doi: 10.3389/fnhum.2013.00109. eCollection 2013. Front Hum Neurosci. 2013. PMID: 23565085 Free PMC article.
-
Advantages and limitations of magnetic source imaging.Brain Topogr. 1991 Winter;4(2):169-80. doi: 10.1007/BF01132773. Brain Topogr. 1991. PMID: 1793690 Review.
-
Overview of MEG.Organ Res Methods. 2019 Jan;22(1):95-115. doi: 10.1177/1094428116676344. Epub 2016 Nov 9. Organ Res Methods. 2019. PMID: 30636863 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources