The great myth of office blood pressure measurement
Abstract
Clinical practice guidelines have traditionally recommended manual blood pressure (BP) measurement in the office setting as the standard method for diagnosing hypertension. In reality, manual BP in routine clinical practice is relatively inaccurate, over-diagnoses hypertension by provoking office-induced increases in BP and correlates poorly with both the awake ambulatory BP and target organ damage. The most recent guidelines recommend 24-h ambulatory BP and home BP for diagnosing hypertension. The advent of automated office BP (AOBP) represents a third alternative to conventional manual BP measurement, one that maintains the role of office BP readings in the diagnosis and management of hypertension. AOBP has three basic principles: multiple readings taken using a fully automated sphygmomanometer with the patient resting quietly alone. AOBP eliminates office-induced hypertension such that the cut-point for a normal AOBP is the same as for the awake ambulatory BP and home BP. As compared to routine manual office BP, AOBP provides more accurate BP readings, is more consistent during repeated office visits and in different settings and correlates better with both the awake ambulatory BP and target organ damage. The advantages of AOBP over manual BP measurement support its use in routine clinical practice.
Comment in
-
Should the measurement of blood pressure in the office be redefined?J Hypertens. 2012 Oct;30(10):1906-8. doi: 10.1097/HJH.0b013e328358a221. J Hypertens. 2012. PMID: 22972158 No abstract available.
Similar articles
-
Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.JAMA Intern Med. 2019 Mar 1;179(3):351-362. doi: 10.1001/jamainternmed.2018.6551. JAMA Intern Med. 2019. PMID: 30715088 Free PMC article.
-
Replacing manual sphygmomanometers with automated blood pressure measurement in routine clinical practice.Clin Exp Pharmacol Physiol. 2014 Jan;41(1):46-53. doi: 10.1111/1440-1681.12149. Clin Exp Pharmacol Physiol. 2014. PMID: 23819734 Review.
-
Automated office blood pressure.Can J Cardiol. 2012 May;28(3):341-6. doi: 10.1016/j.cjca.2011.09.004. Epub 2012 Jan 20. Can J Cardiol. 2012. PMID: 22265230 Review.
-
The conventional versus automated measurement of blood pressure in the office (CAMBO) trial: masked hypertension sub-study.J Hypertens. 2012 Oct;30(10):1937-41. doi: 10.1097/HJH.0b013e328356abd3. J Hypertens. 2012. PMID: 22828087 Clinical Trial.
-
Evaluation of an automated sphygmomanometer for use in the office setting.Blood Press Monit. 2012 Jun;17(3):116-9. doi: 10.1097/MBP.0b013e3283540785. Blood Press Monit. 2012. PMID: 22514038
Cited by
-
Catheter-based Renal Sympathetic Denervation - Long-term Symplicity™ Renal Denervation Clinical Evidence, New Data and Future Perspectives.Interv Cardiol. 2013 Aug;8(2):118-123. doi: 10.15420/icr.2013.8.2.118. Interv Cardiol. 2013. PMID: 29588763 Free PMC article.
-
Comparison of nurse attended and unattended automated office blood pressure with conventional measurement techniques in clinical practice.J Hum Hypertens. 2022 Sep;36(9):833-838. doi: 10.1038/s41371-021-00575-8. Epub 2021 Jul 20. J Hum Hypertens. 2022. PMID: 34285354
-
The Prognostic Role of Automated Office Blood Pressure Measurement in Hypertensive Patients with Chronic Kidney Disease.Healthcare (Basel). 2023 May 9;11(10):1360. doi: 10.3390/healthcare11101360. Healthcare (Basel). 2023. PMID: 37239646 Free PMC article.
-
Methods of Blood Pressure Assessment Used in Milestone Hypertension Trials.Pulse (Basel). 2018 Jul;6(1-2):112-123. doi: 10.1159/000489855. Epub 2018 Jul 18. Pulse (Basel). 2018. PMID: 30283753 Free PMC article. Review.
-
Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.JAMA Intern Med. 2019 Mar 1;179(3):351-362. doi: 10.1001/jamainternmed.2018.6551. JAMA Intern Med. 2019. PMID: 30715088 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials