. 2013 Jan;6(1):78-85.
doi: 10.1007/s12194-012-0172-3. Epub 2012 Aug 8.

Optimal injection rate and volume of contrast medium for observing hemodynamics of a hepatocellular carcinoma structure model

Affiliations

Optimal injection rate and volume of contrast medium for observing hemodynamics of a hepatocellular carcinoma structure model

Kazuhiro Murotani et al. Radiol Phys Technol. 2013 Jan.

Abstract

This study aimed to identify the optimal concentration, injection rate, and total volume of contrast medium (CM) for evaluating the hemodynamics of a hepatocellular carcinoma (HCC) structure model of diameter 35 mm, using multi-level dynamic computed tomography (M-LDCT) with 64 detector rows. A tube was inserted in the model as a simulated vessel. Five CM concentrations were used: non-diluted, 2-, 3-, 6-, and 9-fold diluted. Five regions of interest were placed within the HCC structure model. Time-density curves were created for CM injection rates of 1, 2, and 3 ml/s for 10 s, and for a total volume of 10 ml, followed by saline injection at 1 ml/s. M-LDCT maximum intensity projection images were evaluated by four appraisers using a three-point scale (excellent, 2; good, 1; poor, 0). There was no significant difference between maximum CT values at 2 ml/s for 10 s and those at 3 ml/s; these values were both greater than those at 1 ml/s. The duration of the peak was maintained for longer at 3 ml/s for 10 s (5.2 ± 2.3 s) than at 2 ml/s (3.6 ± 0.9 s). Maximum CT values at 2 ml/s of a total volume of 10 ml were greater than those at 3 ml/s. The highest scores of 7 and 8 were found at 2 and 3 ml/s for 10 s, using 2-, 3-, or 6-fold diluted CM. The most appropriate CM rate for evaluating hemodynamics was 2 ml/s for 10 s, using 2-, 3-, or 6-fold diluted CM.

PubMed Disclaimer