Comparative Study
. 2012 Dec;286(6):1443-52.
doi: 10.1007/s00404-012-2474-4. Epub 2012 Aug 9.

Usefulness of additional fetal magnetic resonance imaging in the prenatal diagnosis of congenital abnormalities

Affiliations
Comparative Study

Usefulness of additional fetal magnetic resonance imaging in the prenatal diagnosis of congenital abnormalities

Ji Sun We et al. Arch Gynecol Obstet. 2012 Dec.

Abstract

Objective: Our aim was to compare the value of fetal magnetic resonance imaging (MRI) with detailed ultrasound in the prenatal diagnosis of congenital abnormalities.

Materials and methods: This retrospective study reviewed the medical records of pregnant women and their neonates who, after ultrasound, were suspected to have congenital abnormalities. They then underwent a detailed ultrasound examination and a fetal MRI in our institutions. Fetal MRI was performed in 81 cases. Each prenatal presumptive diagnosis, based on detailed ultrasound examination and fetal MRI, was compared with the postnatal confirmed diagnosis. In 58 cases, the data collected were confirmed by the postnatal diagnosis.

Results: Supplemental information from fetal MRI was useful in 17 of the 22 cases involving the central nervous system (CNS), two of two cases involving the thorax, nine of nine cases involving the genitourinary system, two of eight cases involving the gastrointestinal system, and ten of ten cases involving complex malformations. Fetal MRI did not provide significantly useful information or facilitate a more accurate diagnosis except for CNS abnormalities.

Conclusion: Fetal MRI was not superior to an ultrasound examination in the prenatal detection of congenital abnormalities. A detailed ultrasound examination performed by experienced obstetricians had satisfactory accuracy in the diagnosis of fetal abnormalities compared with fetal MRI. Fetal MRI might be useful in appropriate cases in Korea. Greater effort is required to increase the ultrasound knowledge and skill of competent obstetricians.