Effect of thermo-mechanical loading on marginal quality and wear of primary molar crowns
- PMID: 22883357
- DOI: 10.1007/BF03262868
Effect of thermo-mechanical loading on marginal quality and wear of primary molar crowns
Abstract
Aim: To evaluate the effect of thermo-mechanical loading (TML) on marginal quality and wear of different crown types for primary molars.
Methods: Eighty extracted human primary molars were used. After preparation, five groups received different crowns (n=16): preformed metal crowns (3M ESPE) and NuSmile crowns (Orthodontic Technologies Inc.) were inserted as preformed metal crowns; as semi-preformed crowns Protemp crowns (3M ESPE) were luted; and as individually manufactured resin composite crowns Filtek Z250 (3M ESPE) and Heliomolar (Ivoclar Vivadent) were used. Specimens were subjected to 2,500 thermal cycles between 5-55(o)C and chewing simulation for 100,000 cycles at 50N at a frequency of 0.5 Hz. Before and after thermo-mechanical loading, impressions of the teeth were taken and replicas were made. The replicas received marginal quality evaluation under a SEM at x200 magnification. Occlusal wear was measured as vertical height loss using a 3-D laser scanning microscope.
Results: After TML, all crowns were intact. The adhesively bonded crowns showed significantly better marginal quality to dentine/cementum compared with GIC luted crowns (p<0.05). Laboratory made crowns showed a good fit and nearly transition-free margins also after TML. Preformed metal crowns showed the significantly lowest wear rates compared to the resin composites (p<0.05). Among the resin composite groups, Protemp exhibited the most pronounced wear depths (p<0.05).
Conclusions: The different crown types under investigation showed a good performance concerning the evaluated parameters marginal quality and wear.
Similar articles
-
The effect of retentive groove, sandblasting and cement type on the retentive strength of stainless steel crowns in primary second molars--an in vitro comparative study.J Indian Soc Pedod Prev Dent. 2012 Jan-Mar;30(1):19-26. doi: 10.4103/0970-4388.95570. J Indian Soc Pedod Prev Dent. 2012. PMID: 22565513
-
Misfit and microleakage of implant-supported crown copings obtained by laser sintering and casting techniques, luted with glass-ionomer, resin cements and acrylic/urethane-based agents.J Dent. 2013 Jan;41(1):90-6. doi: 10.1016/j.jdent.2012.09.014. Epub 2012 Sep 26. J Dent. 2013. PMID: 23022105 Clinical Trial.
-
In vitro investigation of the performance of different restorative materials under cast circumferential clasps for removable dental prostheses.Clin Oral Investig. 2012 Dec;16(6):1659-67. doi: 10.1007/s00784-011-0653-5. Epub 2011 Dec 17. Clin Oral Investig. 2012. PMID: 22173722
-
Wear measurement of dental tissues and materials in clinical studies: A systematic review.Dent Mater. 2018 Jun;34(6):825-850. doi: 10.1016/j.dental.2018.03.002. Epub 2018 Apr 4. Dent Mater. 2018. PMID: 29627079
-
The interaction and interference of preformed metal crowns on magnetic resonance imaging: a scoping review with a systematic methodology.Eur Arch Paediatr Dent. 2021 Dec;22(6):1023-1031. doi: 10.1007/s40368-021-00644-z. Epub 2021 Jun 11. Eur Arch Paediatr Dent. 2021. PMID: 34115334 Free PMC article.
Cited by
-
Long-term Survival Rate and Clinical Quality of Individually Layered Indirect Composite Restorations in Adolescents and Young Adults.J Adhes Dent. 2024 Nov 13;26:263-274. doi: 10.3290/j.jad.b5825410. J Adhes Dent. 2024. PMID: 39534951 Free PMC article.
-
Effect of tooth preparation on microleakage of stainless steel crowns placed on primary mandibular first molars with reduced mesiodistal dimension.J Dent (Tehran). 2015 Jan;12(1):18-24. J Dent (Tehran). 2015. PMID: 26005450 Free PMC article.
-
In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns.Acta Biomater Odontol Scand. 2018 Feb 28;4(1):20-29. doi: 10.1080/23337931.2018.1444995. eCollection 2018. Acta Biomater Odontol Scand. 2018. PMID: 29536024 Free PMC article.
-
Comparison of Fracture Resistance and Microleakage Properties of Two Different Prefabricated Zirconia Crowns After Thermocycling: An In Vitro Study.Biomimetics (Basel). 2025 Aug 16;10(8):538. doi: 10.3390/biomimetics10080538. Biomimetics (Basel). 2025. PMID: 40862911 Free PMC article.
-
Influence of fiber posts on the fracture resistance of endodontically treated premolars with different dental defects.Int J Oral Sci. 2013 Sep;5(3):167-71. doi: 10.1038/ijos.2013.52. Epub 2013 Aug 2. Int J Oral Sci. 2013. PMID: 23907677 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources