Differentiation of white and red thrombus with magnetic resonance imaging: a phantom study
- PMID: 22884048
Differentiation of white and red thrombus with magnetic resonance imaging: a phantom study
Abstract
Background: An early identification of the composition of arterial thrombus may have diagnostic, therapeutic, and prognostic implications. The variation of magnetic resonance (MR) signal intensity between white and red thrombi, especially in the susceptibility sensitive MR sequence, remains unknown. Our research was to evaluate the feasibility of MRI in differentiating of white and red thrombi with a phantom study.
Methods: A total of 12 red and 12 white thrombi were prepared with the venous blood. Examination of the phantom was completed using a 3.0T MR unit, including fluid attenuated inversion recovery (FLAIR) T1, T2-weighted imaging (T2WI), FLAIR T2, T2 gradient echo (T2 GRE) imaging, and susceptibility weighted angiography sequences (SWAN). MR signal intensity patterns of the thrombi were objectively classified as hyperintensity, isointensity and hypointensity, compared with the background agar. The volume of thrombus was calculated and correlated with its signal intensity.
Results: For white thrombi, 11/12 clots showed hyperintensity and 1/12 showed isointensity in FLAIR T1 images. In T2WI, 6/12 clots showed hyperintensity, 3/12 isointensity, and 3/12 hypointensity. In FLAIR T2, 8/12 clots showed hyperintensity and 4/12 showed isointensity. In T2 GRE, 3/12 clots showed hyperintensity and the remaining 9/12 clots showed isointensity. In SWAN, 5/12 clots demonstrated hyperintensity and 7/12 isointensity. For the red thrombus, 12/12 clots demonstrated hyperintensity in FLAIR T1, T2WI, and FLAIR T2 sequences. In T2 GRE and SWAN sequences, 3/12 clots displayed hypointensity and the remaining 9/12 clots showed slight hyperintensity. Thrombi with hypointensity displayed in T2 GRE and SWAN sequences were significantly larger than those with hyperintensity.
Conclusions: Differentiation of white and red thrombi with conventional MR sequence is unreliable, because both kinds of thrombi do not possess unique signal intensity features in these sequences. Red thrombus may or may not show hypointensity in the susceptibility sensitive MR sequences, depending on its size and time course.
Similar articles
-
Relationship between contrast enhancement on fluid-attenuated inversion recovery MR sequences and signal intensity on T2-weighted MR images: visual evaluation of brain tumors.J Magn Reson Imaging. 2005 Jun;21(6):694-700. doi: 10.1002/jmri.20331. J Magn Reson Imaging. 2005. PMID: 15906343
-
Magnetic resonance imaging and histologic findings of experimental cerebral fat embolism.Invest Radiol. 2003 Oct;38(10):625-34. doi: 10.1097/01.rli.0000077055.48406.e2. Invest Radiol. 2003. PMID: 14501490
-
The value of T2*-weighted gradient-echo MRI for the diagnosis of cerebral venous sinus thrombosis.Clin Imaging. 2013 May-Jun;37(3):446-50. doi: 10.1016/j.clinimag.2012.09.003. Epub 2012 Oct 12. Clin Imaging. 2013. PMID: 23068055
-
[Diagnostic imaging of hemangiomas in the brain].Brain Nerve. 2011 Jan;63(1):5-15. Brain Nerve. 2011. PMID: 21228443 Review. Japanese.
-
Diagnosis of cerebral venous thrombosis with echo-planar T2*-weighted magnetic resonance imaging.Arch Neurol. 2002 Jun;59(6):1021-6. doi: 10.1001/archneur.59.6.1021. Arch Neurol. 2002. PMID: 12056941 Review.
Cited by
-
Hyperintense basilar artery on FLAIR MR imaging: diagnostic accuracy and clinical impact in patients with acute brain stem stroke.AJNR Am J Neuroradiol. 2014 Aug;35(8):1520-6. doi: 10.3174/ajnr.A3961. Epub 2014 May 8. AJNR Am J Neuroradiol. 2014. PMID: 24812014 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical