Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Sep;60(3):215-21.
doi: 10.1016/j.jjcc.2012.07.011. Epub 2012 Aug 11.

Incidence and clinical impact of fracture of drug-eluting stents widely used in current clinical practice: comparison with initial platform of sirolimus-eluting stent

Affiliations
Free article
Comparative Study

Incidence and clinical impact of fracture of drug-eluting stents widely used in current clinical practice: comparison with initial platform of sirolimus-eluting stent

Mahn-Won Park et al. J Cardiol. 2012 Sep.
Free article

Abstract

Background: Almost all data on drug-eluting stents (DES) fracture have been derived from initial platform of first-generation DES such as Cypher Bx® (CBX) and Taxus Express®. However, incidence and clinical impact of fracture of newer DES platforms (including Cypher Select®, Taxus® Liberté™, Endeavor®, and Xience™ V) that have been used widely in current clinical practice have not yet been studied.

Methods and results: We analyzed data of 1518 lesions treated with the newer DES platforms in patients who underwent follow-up coronary angiography and compared the results with those of 622 lesions treated with the CBX. The group of newer DES platforms showed significantly lower incidence of stent fracture (SF) than the CBX group (1.25% vs. 5.8%, p<0.001). Binary restenosis (42.1% vs. 6.6%, p<0.001) and target lesion revascularization (TLR) (47.3% vs. 6.2%, p<0.001) related to SF in the newer DES platforms' group were significantly higher than those not related to SF. Notably, SF-related binary restenosis (42.1% vs. 36.1%, p=0.52) and TLR (47.3% vs. 41.6%, p=0.2) were similar between the newer DES platforms' group and the CBX group. On multivariable logistic regression analysis, lesion angulation>45° (odds ratio [OR]: 7.6; 95% confidence interval [CI]: 2.2-26.31), RCA stenting (OR: 5.14; 95% CI: 1.62-16.3) and total stent length (OR: 1.18; 95% CI: 1.03-1.33) were identified as independent predictors for fracture of the newer DES platforms, while closed-cell design stent (Cypher Select®) was not.

Conclusions: Although implantation of the newer DES platforms might reduce the occurrence of SF compared with the CBX, SF-related binary restenosis and TLR remain similarly high. And to predict SF in the newer DES platforms' era, lesion characteristics on index procedure are more important than implanted stent design.

PubMed Disclaimer

Publication types

LinkOut - more resources