Fully automated right ventricular volumetry from ECG-gated coronary CT angiography data: evaluation of prototype software
- PMID: 22890796
- DOI: 10.1007/s10554-012-0109-2
Fully automated right ventricular volumetry from ECG-gated coronary CT angiography data: evaluation of prototype software
Abstract
Enlargement and dysfunction of the right ventricle (RV) is a sign and outcome predictor of many cardiopulmonary diseases. Due to the complex geometry of the RV exact volumetry is cumbersome and time-consuming. We evaluated the performance of prototype software for fully automated RV segmentation and volumetry from cardiac CT data. In 50 retrospectively ECG-gated coronary CT angiography scans the endsystolic (RVVmin) and enddiastolic (RVVmax) volume of the right ventricle was calculated fully automatically by prototype software. Manual slice segmentation by two independent radiologists served as the reference standard. Measurement periods were compared for both methods. RV volumes calculated with the software were in strong agreement with the results from manual slice segmentation (Bland-Altman r = 0.95-0.98; p < 0.001; Lin's correlation Rho = 0.87-0.96, p < 0.001) for RVVmax and RVVmin with excellent interobserver agreement between both radiologists (r = 0.97; p < 0.001). The measurement period was significantly shorter with the software (153 ± 9 s) than with manual slice segmentation (658 ± 211 s). The prototype software demonstrated very good performance in comparison to the reference standard. It promises robust RV volume results and minimizes postprocessing time.
Similar articles
-
Computer-based automated left atrium segmentation and volumetry from ECG-gated coronary CT angiography data: comparison with manual slice segmentation and ultrasound planimetric methods.Rofo. 2010 Dec;182(12):1110-7. doi: 10.1055/s-0029-1245729. Epub 2010 Oct 11. Rofo. 2010. PMID: 20938885
-
Model-based automatic segmentation algorithm accurately assesses the whole cardiac volumetric parameters in patients with cardiac CT angiography: a validation study for evaluating the accuracy of the workstation software and establishing the reference values.Acad Radiol. 2014 May;21(5):639-47. doi: 10.1016/j.acra.2014.01.010. Acad Radiol. 2014. PMID: 24703477
-
Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.Int J Cardiovasc Imaging. 2015 Dec;31 Suppl 2:223-32. doi: 10.1007/s10554-015-0751-6. Epub 2015 Aug 29. Int J Cardiovasc Imaging. 2015. PMID: 26319216
-
Improvement of automated right ventricular segmentation using dual-bolus contrast media injection with 256-slice coronary CT angiography.Acad Radiol. 2014 May;21(5):648-53. doi: 10.1016/j.acra.2014.01.022. Acad Radiol. 2014. PMID: 24703478
-
Right heart on multidetector CT.Br J Radiol. 2011 Dec;84 Spec No 3(Spec Iss 3):S306-23. doi: 10.1259/bjr/59278996. Br J Radiol. 2011. PMID: 22723537 Free PMC article. Review.
Cited by
-
Automated Segmentation of Left Ventricular Myocardium on Cardiac Computed Tomography Using Deep Learning.Korean J Radiol. 2020 Jun;21(6):660-669. doi: 10.3348/kjr.2019.0378. Korean J Radiol. 2020. PMID: 32410405 Free PMC article.
-
Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging.Korean J Radiol. 2019 Jan;20(1):102-113. doi: 10.3348/kjr.2018.0237. Epub 2018 Dec 27. Korean J Radiol. 2019. PMID: 30627026 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources