Comparative Study
. 2013 Feb;29(2):489-96.
doi: 10.1007/s10554-012-0109-2. Epub 2012 Aug 14.

Fully automated right ventricular volumetry from ECG-gated coronary CT angiography data: evaluation of prototype software

Affiliations
Comparative Study

Fully automated right ventricular volumetry from ECG-gated coronary CT angiography data: evaluation of prototype software

Thomas Lehnert et al. Int J Cardiovasc Imaging. 2013 Feb.

Abstract

Enlargement and dysfunction of the right ventricle (RV) is a sign and outcome predictor of many cardiopulmonary diseases. Due to the complex geometry of the RV exact volumetry is cumbersome and time-consuming. We evaluated the performance of prototype software for fully automated RV segmentation and volumetry from cardiac CT data. In 50 retrospectively ECG-gated coronary CT angiography scans the endsystolic (RVVmin) and enddiastolic (RVVmax) volume of the right ventricle was calculated fully automatically by prototype software. Manual slice segmentation by two independent radiologists served as the reference standard. Measurement periods were compared for both methods. RV volumes calculated with the software were in strong agreement with the results from manual slice segmentation (Bland-Altman r = 0.95-0.98; p < 0.001; Lin's correlation Rho = 0.87-0.96, p < 0.001) for RVVmax and RVVmin with excellent interobserver agreement between both radiologists (r = 0.97; p < 0.001). The measurement period was significantly shorter with the software (153 ± 9 s) than with manual slice segmentation (658 ± 211 s). The prototype software demonstrated very good performance in comparison to the reference standard. It promises robust RV volume results and minimizes postprocessing time.

PubMed Disclaimer

Similar articles

Cited by

References

    1. IEEE Trans Med Imaging. 2008 Nov;27(11):1668-81 - PubMed
    1. Crit Care Nurse. 2005 Apr;25(2):52-4, 56-8, 60-2 - PubMed
    1. J Am Coll Cardiol. 2007 Feb 27;49(8):855-62 - PubMed
    1. Radiology. 2008 Jan;246(1):281-7 - PubMed
    1. Radiology. 2008 May;247(2):356-64 - PubMed

MeSH terms

LinkOut - more resources