Comparative Study
. 2013 Feb;23(2):360-6.
doi: 10.1007/s00330-012-2627-7. Epub 2012 Aug 15.

Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations

Affiliations
Comparative Study

Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations

Angeliki Neroladaki et al. Eur Radiol. 2013 Feb.

Abstract

Objectives: The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone.

Methods: Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale.

Results: The radiation dose of ULD-CT was 0.16 ± 0.006 mSv compared with 11.2 ± 2.7 mSv for SDD-CT (P < 0.0001) and 2.7 ± 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (P < 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema.

Conclusion: Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Med Assoc Thai. 2011 Feb;94(2):215-23 - PubMed
    1. Radiology. 2008 Jul;248(1):254-63 - PubMed
    1. Acta Radiol. 2011 Dec 1;52(10):1101-6 - PubMed
    1. Radiology. 2004 May;231(2):440-5 - PubMed
    1. Radiology. 2008 Mar;246(3):697-722 - PubMed

Publication types