Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Oct;21(7):535-9.
doi: 10.1111/j.1532-849X.2012.00871.x. Epub 2012 Aug 20.

Straight and offset implant placement under axial and nonaxial loads in implant-supported prostheses: strain gauge analysis

Affiliations

Straight and offset implant placement under axial and nonaxial loads in implant-supported prostheses: strain gauge analysis

Celina Wanderley Abreu et al. J Prosthodont. 2012 Oct.

Abstract

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O).

Materials and methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (με). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05).

Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (με) (183.2 ± 93.64) and axial straight line (285.3 ± 61.04) and differences between nonaxial 1 mm offset (201.0 ± 50.24) and nonaxial 1 mm straight line (315.8 ± 59.28).

Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

PubMed Disclaimer

Publication types

LinkOut - more resources