Improving the quality of cardiopulmonary resuscitation by training dedicated cardiac arrest teams incorporating a mechanical load-distributing device at the emergency department
- PMID: 22906966
- DOI: 10.1016/j.resuscitation.2012.07.033
Improving the quality of cardiopulmonary resuscitation by training dedicated cardiac arrest teams incorporating a mechanical load-distributing device at the emergency department
Abstract
Objective: Determine if implementing cardiac arrest teams trained with a 'pit-crew' protocol incorporating a load-distributing band mechanical CPR device (Autopulse™ ZOLL) improves the quality of CPR, as determined by no-flow ratio (NFR) in the first 10min of resuscitation.
Methods: A phased, prospective, non-randomized, before-after cohort evaluation. Data collection was from April 2008 to February 2011. There were 100 before and 148 after cases. Continuous video and chest compression data of all study subjects were analyzed. All non-traumatic, collapsed patients aged 18 years and above presenting to the emergency department were eligible. Primary outcome was NFR. Secondary outcomes were return of spontaneous circulation (ROSC), survival to hospital admission and neurological outcome at discharge.
Main results: After implementation, mean total NFR for the first 5min decreased from 0.42 to 0.27 (decrease=0.15, 95% CI 0.10-0.19, p<0.005), and from 0.24 to 0.18 (decrease=0.06, 95% CI 0.01-0.11, p=0.02) for the next 5min. The mean time taken to apply Autopulse™ decreased from 208.8s to 141.6s (decrease=67.2, 95% CI, 22.3-112.1, p<0.005). The mean CPR ratio increased from 46.4% to 88.4% (increase=41.9%, 95% CI 36.9-46.9, p<0.005) and the mean total NFR for the first 10min decreased from 0.33 to 0.23 (decrease=0.10, 95% CI 0.07-0.14, p<0.005).
Conclusion: Implementation of cardiac arrest teams was associated with a reduction in NFR in the first 10min of resuscitation. Training cardiac arrest teams in a 'pit-crew' protocol may improve the quality of CPR at the ED.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
Cardiopulmonary resuscitation interruptions with use of a load-distributing band device during emergency department cardiac arrest.Ann Emerg Med. 2010 Sep;56(3):233-41. doi: 10.1016/j.annemergmed.2010.01.004. Epub 2010 Mar 12. Ann Emerg Med. 2010. PMID: 20138401
-
The analysis of efficacy for AutoPulse™ system in flying helicopter.Resuscitation. 2013 Aug;84(8):1045-50. doi: 10.1016/j.resuscitation.2013.01.014. Epub 2013 Jan 23. Resuscitation. 2013. PMID: 23353137
-
Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation.JAMA. 2006 Jun 14;295(22):2629-37. doi: 10.1001/jama.295.22.2629. JAMA. 2006. PMID: 16772626
-
Approaches to improving cardiac arrest resuscitation performance.Curr Opin Crit Care. 2010 Jun;16(3):196-202. doi: 10.1097/MCC.0b013e328338c121. Curr Opin Crit Care. 2010. PMID: 20305553 Review.
-
[Automatic load-distributing band CPR (AutoPulse™) in prone position, feasible?].Anaesthesist. 2021 Mar;70(3):247-249. doi: 10.1007/s00101-020-00851-1. Anaesthesist. 2021. PMID: 32968843 Free PMC article. Review. German.
Cited by
-
Mechanical chest compression: an alternative in helicopter emergency medical services?Intern Emerg Med. 2015 Sep;10(6):715-20. doi: 10.1007/s11739-015-1238-0. Epub 2015 Apr 28. Intern Emerg Med. 2015. PMID: 25918109
-
[Mechanical resuscitation assist devices].Anaesthesist. 2014 Mar;63(3):186-97. doi: 10.1007/s00101-013-2265-8. Anaesthesist. 2014. PMID: 24569931 Review. German.
-
Cardiac arrest in the perioperative period: a consensus guideline for identification, treatment, and prevention from the European Society of Anaesthesiology and Intensive Care and the European Society for Trauma and Emergency Surgery.Eur J Trauma Emerg Surg. 2023 Oct;49(5):2031-2046. doi: 10.1007/s00068-023-02271-3. Eur J Trauma Emerg Surg. 2023. PMID: 37430174 Free PMC article.
-
The System-Wide Effect of Real-Time Audiovisual Feedback and Postevent Debriefing for In-Hospital Cardiac Arrest: The Cardiopulmonary Resuscitation Quality Improvement Initiative.Crit Care Med. 2015 Nov;43(11):2321-31. doi: 10.1097/CCM.0000000000001202. Crit Care Med. 2015. PMID: 26186567 Free PMC article. Clinical Trial.
-
Mechanical Cardiopulmonary Resuscitation and Hospital Survival Among Adult Patients With Nontraumatic Out-of-Hospital Cardiac Arrest Attending the Emergency Department: A Prospective, Multicenter, Observational Study in Japan (SOS-KANTO [Survey of Survivors after Out-of-Hospital Cardiac Arrest in Kanto Area] 2012 Study).J Am Heart Assoc. 2017 Oct 31;6(11):e007420. doi: 10.1161/JAHA.117.007420. J Am Heart Assoc. 2017. PMID: 29089341 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical