The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients
- PMID: 22910834
- DOI: 10.1378/chest.12-1274
The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients
Abstract
Background: The clinical assessment of intravascular volume status and volume responsiveness is one of the most difficult tasks in critical care medicine. Furthermore, accumulating evidence suggests that both inadequate and overzealous fluid resuscitation are associated with poor outcomes. The objective of this study was to determine the predictive value of passive leg raising (PLR)- induced changes in stroke volume index (SVI) as assessed by bioreactance in predicting volume responsiveness in a heterogenous group of patients in the ICU. A secondary end point was to evaluate the change in carotid Doppler fl ow following the PLR maneuver.
Methods: During an 8-month period, we collected clinical, hemodynamic, and carotid Doppler data on hemodynamically unstable patients in the ICU who underwent a PLR maneuver as part of our resuscitation protocol. A patient whose SVI increased by . 10% following a fluid challenge was considered a fluid responder.
Results: A complete data set was available for 34 patients. Twenty-two patients (65%) had severe sepsis/septic shock, whereas 21 (62%) required vasopressor support and 19 (56%) required mechanical ventilation. Eighteen patients (53%) were volume responders. The PLR maneuver had a sensitivity of 94% and a specificity of 100% for predicting volume responsiveness (one false negative result). In the 19 patients undergoing mechanical ventilation, the stroke volume variation was 18.0% 5.1% in the responders and 14.8% 3.4% in the nonresponders ( P 5 .15). Carotid blood fl ow increased by 79% 32% after the PLR in the responders compared with 0.1% 14% in the nonresponders ( P , .0001). There was a strong correlation between the percent change in SVI by PLR and the concomitant percent change in carotid blood fl ow ( r 5 0.59, P 5 .0003). Using a threshold increase in carotid Doppler fl ow imaging of 20% for predicting volume responsiveness, there were two false positive results and one false negative result, giving a sensitivity and specificity of 94% and 86%, respectively. We noted a significant increase in the diameter of the common carotid artery in the fluid responders.
Conclusions: Monitoring the hemodynamic response to a PLR maneuver using bioreactance provides an accurate method of assessing volume responsiveness in critically ill patients. In addition, the study suggests that changes in carotid blood fl ow following a PLR maneuver may be a useful adjunctive method for determining fluid responsiveness in hemodynamically unstable patients.
Similar articles
-
Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock.Crit Care Med. 2018 Nov;46(11):e1040-e1046. doi: 10.1097/CCM.0000000000003356. Crit Care Med. 2018. PMID: 30134304 Free PMC article.
-
[The prediction value of noninvasive bioreactance-based passive leg raising test in assessing fluid responsiveness in elderly patients with sepsis].Zhonghua Nei Ke Za Zhi. 2015 Feb;54(2):130-3. Zhonghua Nei Ke Za Zhi. 2015. PMID: 25907844 Chinese.
-
[The value of passive leg raising test in predicting fluid responsiveness in patients with sepsis-induced cardiac dysfunction].Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015 Sep;27(9):729-34. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015. PMID: 26955698 Chinese.
-
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis.Intensive Care Med. 2016 Dec;42(12):1935-1947. doi: 10.1007/s00134-015-4134-1. Epub 2016 Jan 29. Intensive Care Med. 2016. PMID: 26825952
-
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?JAMA. 2016 Sep 27;316(12):1298-309. doi: 10.1001/jama.2016.12310. JAMA. 2016. PMID: 27673307 Review.
Cited by
-
The Correlation between Carotid Artery Corrected Flow Time and Velocity Time Integral during Central Blood Volume Loss and Resuscitation.J Med Ultrasound. 2023 Dec 7;31(4):309-313. doi: 10.4103/jmu.jmu_80_23. eCollection 2023 Oct-Dec. J Med Ultrasound. 2023. PMID: 38264586 Free PMC article.
-
Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects.Scand J Trauma Resusc Emerg Med. 2018 Dec 4;26(1):104. doi: 10.1186/s13049-018-0571-5. Scand J Trauma Resusc Emerg Med. 2018. PMID: 30514343 Free PMC article.
-
Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.BMC Anesthesiol. 2018 Nov 13;18(1):168. doi: 10.1186/s12871-018-0635-0. BMC Anesthesiol. 2018. PMID: 30424730 Free PMC article.
-
In training emergency physicians the carotid artery Doppler with passive leg raise, does previous sonographic experience influence scan time and competency?Australas J Ultrasound Med. 2020 Apr 16;24(1):20-26. doi: 10.1002/ajum.12204. eCollection 2021 Feb. Australas J Ultrasound Med. 2020. PMID: 34760607 Free PMC article.
-
Functional haemodynamic monitoring.Curr Opin Crit Care. 2014 Jun;20(3):288-93. doi: 10.1097/MCC.0000000000000090. Curr Opin Crit Care. 2014. PMID: 24722057 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical