Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine
- PMID: 22918571
- DOI: 10.1007/s10554-012-0110-9
Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine
Abstract
To compare image quality of coronary CT angiography in step-and-shoot mode at the diastolic phase at low heart rates (<70 bpm) and systolic phase at high heart rates (≥70 bpm). We prospectively included 96 consecutive patients then excluded 5 patients with arrhythmia. Coronary CT-angiography was performed using a dual-source 128-slice CT machine, at the diastolic phase in the 55 patients with heart rates <70 bpm (group D) and at the systolic phase in the 36 patients with heart rates ≥70 (group S). Image quality was scored on a 5 point-scale (1, not interpretable; 2, insufficient for diagnosis; 3, fair, sufficient for diagnosis; 4, good; 5, excellent). In addition, we compared the number of stair-step artifacts in the two groups. Mean image quality score was 4 (0.78) in group D and 4.1 (0.34) in group S (NS), with an unequal distribution (p = 0.01). Step artifacts were seen in 44 % of group D and 18 % of group S patients (p = 0.02). In 3 group D patients and no group S patients, the image score was <3 due to artifacts, requiring repeat CT-angiography. When performing dual-source 128-slice CT-angiography, step-and-shoot acquisition provides comparable mean image quality in systole, with less variability and fewer stair-step artifacts, compared to diastole. This method may be feasible at any heart rate in most patients in sinus rhythm, allowing low-dose prospective acquisition without beta-blocker premedication.
Similar articles
-
Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort study.Int J Cardiovasc Imaging. 2013 Aug;29(6):1361-70. doi: 10.1007/s10554-013-0208-8. Epub 2013 Mar 24. Int J Cardiovasc Imaging. 2013. PMID: 23526082
-
Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition.Int J Cardiovasc Imaging. 2012 Jun;28(5):1217-25. doi: 10.1007/s10554-011-9921-3. Epub 2011 Jul 10. Int J Cardiovasc Imaging. 2012. PMID: 21744246
-
High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.Int J Cardiovasc Imaging. 2014 Aug;30(6):1173-9. doi: 10.1007/s10554-014-0445-5. Epub 2014 May 11. Int J Cardiovasc Imaging. 2014. PMID: 24816910
-
Acquisition and Reconstruction Techniques for Coronary CT Angiography: Current Status and Trends over the Past Decade.Radiographics. 2025 Jul;45(7):e240083. doi: 10.1148/rg.240083. Radiographics. 2025. PMID: 40504731 Review.
-
The "post-64" era of coronary CT angiography: understanding new technology from physical principles.Radiol Clin North Am. 2009 Jan;47(1):79-90. doi: 10.1016/j.rcl.2008.11.001. Radiol Clin North Am. 2009. PMID: 19195535 Free PMC article. Review.
Cited by
-
Diagnostic quality of dual-source coronary CT examinations performed without heart rate control: importance of obesity and heart rate on image quality.J Comput Assist Tomogr. 2014 Nov-Dec;38(6):949-55. doi: 10.1097/RCT.0000000000000135. J Comput Assist Tomogr. 2014. PMID: 25032805 Free PMC article.
-
Age-related differences in image quality of prospectively ECG-triggered axial and helical scans for coronary CT angiography.Radiol Phys Technol. 2016 Jul;9(2):214-20. doi: 10.1007/s12194-016-0351-8. Epub 2016 Mar 16. Radiol Phys Technol. 2016. PMID: 26984733 Clinical Trial.
-
Increasing the rate of datasets amenable to CTFFR and quantitative plaque analysis: Value of software for reducing stair-step artifacts demonstrated in photon-counting detector CT.Eur J Radiol Open. 2024 Jun 4;12:100574. doi: 10.1016/j.ejro.2024.100574. eCollection 2024 Jun. Eur J Radiol Open. 2024. PMID: 38882632 Free PMC article.
-
Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography.Int J Cardiovasc Imaging. 2016 Jan;32(1):91-100. doi: 10.1007/s10554-015-0755-2. Epub 2015 Sep 3. Int J Cardiovasc Imaging. 2016. PMID: 26335369 Free PMC article.
-
Relationship between heart rate and optimal reconstruction phase in coronary CT angiography performed on a 256-slice multidetector CT.Br J Radiol. 2019 Sep;92(1101):20180945. doi: 10.1259/bjr.20180945. Epub 2019 Jul 29. Br J Radiol. 2019. PMID: 31322906 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous