Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis
- PMID: 22920538
- DOI: 10.1016/j.dental.2012.07.160
Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis
Abstract
Objectives: Occlusal overloading is one of the causes of peri-implant bone resorption, and many studies on stress distribution in the peri-implant bone by three-dimensional finite element analysis (3D FEA) have been performed. However, the FEA models previously reported were simplified and far from representing what occurs in clinical situations. In this study, 3D FEA was conducted with simulation of the complex structure of dental implants, and the influences of neck design and connections with an abutment on peri-implant bone stress and abutment micromovement were investigated.
Methods: Three types of two-piece implant CAD models were designed: external joint with a conical tapered neck (EJ), internal joint with a straight neck (IJ), and conical joint with a reverse conical neck (CJ). 3D FEA was performed with the setting of a "contact" condition at the component interface, and stress distribution in the peri-implant bone and abutment micromovement were analyzed.
Results: The shear stress was concentrated on the mesiodistal side of the cortical bone for EJ. EJ had the largest amount of abutment micromovement. While the von Mises and shear stresses around the implant neck were concentrated on the labial bone for IJ, they were distributed on the mesiodistal side of the cortical bone for CJ. CJ had the least amount of abutment micromovement.
Significance: Implants with a conical joint with an abutment and reverse conical neck design may effectively control occlusal overloading on the labial bone and abutment micromovement.
Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.J Periodontol. 2014 Sep;85(9):e333-8. doi: 10.1902/jop.2014.140107. Epub 2014 May 17. J Periodontol. 2014. PMID: 24835549
-
A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.J Oral Implantol. 2008;34(1):1-6. doi: 10.1563/1548-1336(2008)34[1:AFEAOT]2.0.CO;2. J Oral Implantol. 2008. PMID: 18390236
-
Influences of internal tapered abutment designs on bone stresses around a dental implant: three-dimensional finite element method with statistical evaluation.J Periodontol. 2012 Jan;83(1):111-8. doi: 10.1902/jop.2011.110087. Epub 2011 May 12. J Periodontol. 2012. PMID: 21563947
-
Effects of occlusal forces on the peri-implant-bone interface stability.Periodontol 2000. 2019 Oct;81(1):179-193. doi: 10.1111/prd.12291. Periodontol 2000. 2019. PMID: 31407438 Review.
-
The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies.J Oral Maxillofac Res. 2016 Sep 9;7(3):e4. doi: 10.5037/jomr.2016.7304. eCollection 2016 Jul-Sep. J Oral Maxillofac Res. 2016. PMID: 27833729 Free PMC article. Review.
Cited by
-
Automated Remodelling of Connectors in Fixed Partial Dentures.Dent J (Basel). 2023 Oct 27;11(11):252. doi: 10.3390/dj11110252. Dent J (Basel). 2023. PMID: 37999016 Free PMC article.
-
The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis.J Dent Sci. 2020 Dec;15(4):466-471. doi: 10.1016/j.jds.2019.12.003. Epub 2019 Dec 31. J Dent Sci. 2020. PMID: 33505618 Free PMC article.
-
Comparative Biomechanical Evaluation of Novel Screwless Retained Dental Implant Prosthesis: A 3D Finite Element Analysis.J Funct Biomater. 2025 Jan 22;16(2):39. doi: 10.3390/jfb16020039. J Funct Biomater. 2025. PMID: 39997573 Free PMC article.
-
Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study.Materials (Basel). 2022 Aug 25;15(17):5866. doi: 10.3390/ma15175866. Materials (Basel). 2022. PMID: 36079245 Free PMC article.
-
Novel Design and Finite Element Analysis of Diamond-like Porous Implants with Low Stiffness.Materials (Basel). 2021 Nov 16;14(22):6918. doi: 10.3390/ma14226918. Materials (Basel). 2021. PMID: 34832321 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous