The helical flow pump with a hydrodynamic levitation impeller

Affiliations

The helical flow pump with a hydrodynamic levitation impeller

Yusuke Abe et al. J Artif Organs. 2012 Dec.

Abstract

The helical flow pump (HFP) is a novel rotary blood pump invented for developing a total artificial heart (TAH). The HFP with a hydrodynamic levitation impeller, which consists of a multi-vane impeller involving rotor magnets, stator coils at the core position, and double helical-volute pump housing, was developed. Between the stator and impeller, a hydrodynamic bearing is formed. Since the helical volutes are formed at both sides of the impeller, blood flows with a helical flow pattern inside the pump. The developed HFP showed maximum output of 19 l/min against 100 mmHg of pressure head and 11 % maximum efficiency. The profile of the H-Q (pressure head vs. flow) curve was similar to that of the undulation pump. Hydrodynamic levitation of the impeller was possible with higher than 1,000 rpm rotation speed. The normalized index of the hemolysis ratio of the HFP to centrifugal pump (BPX-80) was from 2.61 to 8.07 depending on the design of the bearing. The HFP was implanted in two goats with a left ventricular bypass method. After surgery, hemolysis occurred in both goats. The hemolysis ceased on postoperative days 14 and 9, respectively. In the first experiment, no thrombus was found in the pump after 203 days of pumping. In the second experiment, a white thrombus was found in the pump after 23 days of pumping. While further research and development are necessary, we are expecting to develop an excellent TAH with the HFP.

PubMed Disclaimer

Similar articles

Cited by

References

    1. N Engl J Med. 2001 Nov 15;345(20):1435-43 - PubMed
    1. J Artif Organs. 2007;10(2):60-70 - PubMed
    1. Artif Organs. 2001 May;25(5):411-3 - PubMed
    1. Artif Organs. 2004 Oct;28(10):953-8 - PubMed
    1. Ann Thorac Surg. 2001 Mar;71(3 Suppl):S92-7; discussion S114-5 - PubMed

Publication types

LinkOut - more resources