Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Nov;38(11):1938-48.
doi: 10.1016/j.ultrasmedbio.2012.07.013. Epub 2012 Aug 25.

Estimating the delivery efficiency of drug-loaded microbubbles in cancer cells with ultrasound and bioluminescence imaging

Affiliations

Estimating the delivery efficiency of drug-loaded microbubbles in cancer cells with ultrasound and bioluminescence imaging

Ai-Ho Liao et al. Ultrasound Med Biol. 2012 Nov.

Abstract

The application of drug-loaded microbubbles (MBs) in combination with ultrasound (US), which results in an increase in capillary permeability at the site of US-sonication-induced MB destruction, may be an efficient method of localized drug delivery. This study investigated the mechanism underlying the US-mediated release of luciferin-loaded MBs through the blood vessels to targeted cells using an in vivo bioluminescence imaging (BLI) system. The luciferin-loaded MBs comprised an albumin shell with a diameter of 1234 ± 394 nm (mean ± SD) and contained 2.48 × 10⁹ bubbles/mL; within each MB, the concentration of encapsulated luciferin was 1.48 × 10⁻¹⁰ mg/bubble. The loading efficiency of luciferin in MBs was only about 19.8%, while maintaining both the bioluminescence and acoustic properties. In vitro and in vivo BLI experiments were performed to evaluate the US-mediated release of luciferin-loaded MBs. For in vitro results, the increase in light emission of luciferin-loaded albumin-shelled MBs after destruction via US sonication (6.24 ± 0.72 × 10⁷ photons/s) was significantly higher than that in the luciferin-loaded albumin-shelled MBs (3.11 ± 0.33 × 10⁷ photons/s) (p < 0.05). The efficiency of the US-mediated release of luciferin-loaded MBs in 4T1-luc2 tumor-bearing mice was also estimated. The signal intensity of the tumor with US destruction at 3 W/cm² for 30 s was significantly higher than without US destruction at 3 (p = 0.025), 5 (p = 0.013), 7 (p = 0.012) and 10 (p = 0.032) min after injecting luciferin-loaded albumin-shelled MBs. The delivery efficiency was, thus, improved with US-mediated release, allowing reduction of the total injection dose of luciferin.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources