Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jan 1;85(1):190-5.
doi: 10.1016/j.ijrobp.2012.03.041. Epub 2012 Aug 25.

Clinical and dosimetric predictors of radiation pneumonitis in a large series of patients treated with stereotactic body radiation therapy to the lung

Affiliations

Clinical and dosimetric predictors of radiation pneumonitis in a large series of patients treated with stereotactic body radiation therapy to the lung

Ryan Baker et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To report clinical and dosimetric factors predictive of radiation pneumonitis (RP) in patients receiving lung stereotactic body radiation therapy (SBRT) from a series of 240 patients.

Methods and materials: Of the 297 isocenters treating 263 patients, 240 patients (n=263 isocenters) had evaluable information regarding RP. Age, gender, current smoking status and pack-years, O2 use, Charlson Comorbidity Index, prior lung radiation therapy (yes/no), dose/fractionation, V5, V13, V20, Vprescription, mean lung dose, planning target volume (PTV), total lung volume, and PTV/lung volume ratio were recorded.

Results: Twenty-nine patients (11.0%) developed symptomatic pneumonitis (26 grade 2, 3 grade 3). The mean V20 was 6.5% (range, 0.4%-20.2%), and the average mean lung dose was 5.03 Gy (0.547-12.2 Gy). In univariable analysis female gender (P=.0257) and Charlson Comorbidity index (P=.0366) were significantly predictive of RP. Among dosimetric parameters, V5 (P=.0186), V13 (P=.0438), and Vprescription (where dose=60 Gy) (P=.0128) were significant. There was only a trend toward significance for V20 (P=.0610). Planning target volume/normal lung volume ratio was highly significant (P=.0024). In multivariable analysis the clinical factors of female gender, pack-years smoking, and larger gross internal tumor volume and PTV were predictive (P=.0094, .0312, .0364, and .052, respectively), but no dosimetric factors were significant.

Conclusions: Rate of symptomatic RP was 11%. Our mean lung dose was <600 cGy in most cases and V20<10%. In univariable analysis, dosimetric factors were predictive, while tumor size (or tumor/lung volume ratio) played a role in multivariable and univariable and analysis, respectively.

PubMed Disclaimer

MeSH terms