The problem of indeterminate microvolt T-wave alternans results in patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator implantation in the primary prevention of sudden cardiac death
- PMID: 22933211
The problem of indeterminate microvolt T-wave alternans results in patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator implantation in the primary prevention of sudden cardiac death
Abstract
Background: Microvolt T-wave alternans (MTWA) is a recommended noninvasive diagnostic test for predicting the risk of sudden cardiac death (SCD). However, about 6% to 41% of MTWA results are indeterminate. The causes, interpretation and clinical significance of these results have not been not clearly established.
Aim: To assess frequency, causes, and prognostic significance of indeterminate MTWA results in a group of patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator (ICD) placement in the primary prevention of SCD.
Methods: Patients with left ventricular ejection fraction (LVEF) ≤ 35% underwent MTWA evaluation during a treadmill exercise test (CH2000 system, Cambridge Heart Inc. Bedford MA, USA). MTWA results (spectral analysis) were categorised as positive, negative, or indeterminate (MTWApos, MTWAneg, and MTWAnd, respectively). Patients were followed up for the occurrence of SCD, ventricular tachycardia (VT), and ventricular fibrillation (VF).
Results: Mean age of participants (n = 93) was 63 ± 13 years, an ischaemic cause of left ventricular dysfunction was present in 70 (75%) patients, and average LVEF was 30 ± 7%. MTWApos was found in 27 (29%) patients, MTWAneg in 41 (44%) patients, and MTWAnd in 25 (27%) patients. Causes of MTWAnd included inability to achieve a diagnostic HR in 12 (48%) patients, ventricular ectopy in 5 (20%) patients, nonsustained alternans in 3 (12%) patients, and technical factors (artifacts due to a high noise level) in 5 patients (20% of indeterminate results, 5.4% of the whole study group). During follow-up, 8 SCD/VT/VF events were noted (4 patients with MTWApos and 4 patients with MTWAnd due to patient-related factors). The rate of SCD/VT/VF was 35% in patients with MTWApos and 34.6% in MTWAnd due to patients-related factors, significantly higher compared to those with MTWAneg or MTWAnd due to technical factors (p 〈 0.05).
Conclusions: Although the proportion of indeterminate MTWA results in patients with left ventricular dysfunction referred for ICD implantation in the primary prevention of SCD was high, the proportion of indeterminate MTWA results due to technical factors, probably of no prognostic significance, was small.
Similar articles
-
[Negative result of microvolt T-wave alternans test is helpful in scheduling the order of cardioverter-defibrillator implantation in primary prevention of sudden cardiac death in individuals with the left ventricular systolic dysfunction].Pol Merkur Lekarski. 2012 Oct;33(196):193-7. Pol Merkur Lekarski. 2012. PMID: 23272605 Polish.
-
Microvolt T-wave alternans and other noninvasive predictors of serious arrhythmic events in patients with an implanted cardioverter-defibrillator.Kardiol Pol. 2012;70(5):447-55. Kardiol Pol. 2012. PMID: 22623232
-
[Positive microvolt T-wave alternans as a marker of ventricular arrhythmia trigering during cardioverter-defibrillator implantation].Pol Merkur Lekarski. 2006 Oct;21(124):310-3. Pol Merkur Lekarski. 2006. PMID: 17205766 Polish.
-
Ability of microvolt T-wave alternans to modify risk assessment of ventricular tachyarrhythmic events: a meta-analysis.Am Heart J. 2012 Mar;163(3):354-64. doi: 10.1016/j.ahj.2011.11.021. Am Heart J. 2012. PMID: 22424005 Review.
-
Can microvolt T-wave alternans testing reduce unnecessary defibrillator implantation?Nat Clin Pract Cardiovasc Med. 2005 Oct;2(10):522-8. doi: 10.1038/ncpcardio0323. Nat Clin Pract Cardiovasc Med. 2005. PMID: 16186850 Review.
MeSH terms
LinkOut - more resources
Medical