Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012;5(4):505-9.
doi: 10.3980/j.issn.2222-3959.2012.04.19. Epub 2012 Aug 18.

Corneal white-to-white distance and mesopic pupil diameter

Affiliations

Corneal white-to-white distance and mesopic pupil diameter

Hasan Basri Cakmak et al. Int J Ophthalmol. 2012.

Abstract

Aim: To study the relationship between corneal white-to-white (WTW) distance and mesopic pupil diameter.

Methods: This study is composed of 30 cases that underwent photorefractive keratotomy (PRK). Pupil size measurements were performed with Schwind ORK wavefront analyzer in mesopic conditions. WTW distance was measured with a measuring caliper. Also, A-scan ultrasound examination was performed in all patients. The relationship among the mesopic pupil diameter and age, sex, axial length, lens thickness, anterior chamber depth(ACD), horizontal WTW distance, vertical WTW distance, spherical equivalent, and average keratometry were analyzed with univariate and multivariate regression analysis.

Results: Mean pupil diameter was (6.39±0.80)mm (range: 3.70mm-7.73mm). Horizontal WTW distance measurements were between 11.00mm and 12.50mm and mean horizontal WTW distance was (11.79±0.43)mm. On the other hand, vertical WTW distances ranged between 10.00mm and 13.00mm, and their mean was (11.42±0.72)mm. Bivariate correlation between pupil diameter and other variables showed that the axial length, ACD, spherical equivalent, and horizontal WTW distance had a moderate correlation with mesopic pupil diameter. Multiple regression analysis revealed that spherical equivalent and horizontal WTW distances were significantly associated with mesopic pupil diameter (R=0.598, R(2)=0.358 P=0.02).

Conclusion: This study shows that mesopic pupil diameter is closely related to horizontal WTW distance. These two factors must be taken in consideration together in preoperative ablation zone planning.

Keywords: mesopic pupil diameter; photorefractive keratectomy; white-to-white distance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Villa C, Gutierrez R, Jimenez JR, Gonzalez-Meijome JM. Night vision disturbances after successful LASIK surgery. Br J Ophthalmol. 2007;91(8):1031–1037. - PMC - PubMed
    1. Holladay JT, Janes JA. Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis. J Cataract Refract Surg. 2002;28(6):942–947. - PubMed
    1. Boxer Wachler BS. Effect of pupil size on visual function under monocular and binocular conditions in LASIK and non-LASIK patients. J Cataract Refract Surg. 2003;29(2):275–278. - PubMed
    1. de Silva DJ, Khaw PT, Brookes JL. Long term outcome of primary congenital glaucoma. J AAPOS. 2011;15(2):148–152. - PubMed
    1. Allemann N, Chamon W, Tanaka HM, Mori ES, Campos M, Schor P, Baïkoff G. Myopic angle-supported intraocular lenses: two-year follow-up. Ophthalmology. 2000;107(8):1549–1554. - PubMed

LinkOut - more resources