Breathing patterns in lambs after oleic acid lung injury utilizing respiratory inductive plethysmography
- PMID: 2293973
- DOI: 10.1097/00003246-199001000-00019
Breathing patterns in lambs after oleic acid lung injury utilizing respiratory inductive plethysmography
Abstract
We measured breathing patterns utilizing a respiratory inductive plethysmograph (RIP) in seven healthy nonsedated lambs after an iv infusion of oleic acid (50 mg/kg) to induce acute pulmonary edema. Our single position graphic (SPG) calibration technique was employed for gain factor calculation. Accuracy was validated by the simultaneous volume measurement of RIP and integrated pneumotachography (PNT). Of a total 840 validation breaths, 467 (56%) were within 5% of PNT, 734 (87%) were within 10%, and 834 (99.9%) were within 20%. In each study baseline physiologic and breathing pattern data were collected and also at 15, 30, 60, 90, 150, and 210 min postoleic acid infusion. Validation of RIP accuracy before each data collection revealed 29% required new gain factor calculation. Recalibration was done within 5 min. Excluding respiratory frequency, which remained at 30% above baseline, variables were not significantly different than baseline measurements at the 210-min interval. Results suggest that calibration of RIP using our SPG technique is a time-efficient method and that RIP can accurately measure breathing patterns, providing an additional tool for assessment of experimental lung injury in lambs.
Similar articles
-
Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs.Chest. 1988 Aug;94(2):325-8. doi: 10.1378/chest.94.2.325. Chest. 1988. PMID: 3396411
-
Calibration of respiratory inductive plethysmography in lambs receiving intermittent mandatory mechanical ventilation.Crit Care Med. 1988 Feb;16(2):161-4. doi: 10.1097/00003246-198802000-00013. Crit Care Med. 1988. PMID: 3277774
-
Breathing patterns in infants utilizing respiratory inductive plethysmography.Chest. 1986 May;89(5):717-22. doi: 10.1378/chest.89.5.717. Chest. 1986. PMID: 3698701
-
Calibration of respiratory inductive plethysmography in spontaneously breathing lambs and piglets.J Dev Physiol. 1986 Aug;8(4):255-8. J Dev Physiol. 1986. PMID: 3760483
-
Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs.J Dev Physiol. 1989 Dec;12(6):347-52. J Dev Physiol. 1989. PMID: 2640229
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous